Tested on the R1.05 test server 2026-10-09..12 with a user project (own
objects only); not yet on CI-Eng-Sample (ISS-188). Only results that
were tested are included; inferences, code-only and manual-only points
and the untested sample layout change were left out.
- layouts: 'logout' is a secondary logout, always disabled on the R1.05
web client; 'exit' closes the window and ends the session (ISS-182).
- create-display: R1.05 web client table (String items in text vs
textField, fixed text alignment, start-hidden limits ISS-183, two
visibility conditions, On entry display actions, rectangle blinking,
verified connections, first load).
- java-class 4a: signal arrays at scale, write on change, attribute
arrays, offline javac/javap check; change-reset-class: new signals need
the object recreated, attributes lost (ISS-185); opcdbg reset in cmd,
TRIGGER_1 via dssqld -m.
- string-items (ISS-187), users-groups, modbus-station (400 registers,
comm loss), export-dataset (NAME range filter), item-alarming.
- new task system-management/package-project.md; tools/ModbusSim.java
(tested on R1.05: FC03/04/06/16, exceptions, modes); AMSI (ISS-186).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Classes, sub-items, Modbus loopback and OPC UA loopback pass on R1.05.
New examples/CI-Eng-Sample/shared/: snapshot, reduced load/remove,
test and DSS temp-file cleanup scripts for shared servers. Before/after
snapshot identical; ISS-091 (dss_*.tmp left in tls\lst); ISS-080 note.
Certificate files of the test await deletion by the user.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
New knowledge/r105-verification.md lists the R1.05 functions not available
on the test server (not tested) and the read-only steps prepared for the
user to verify on the server or in the GUI (eqpdbg, setup_check.ps1,
Engineering Module forms) plus the CI-Eng-Sample load decision.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Read-only re-check on the shared R1.05 test server plus a diff of the
R1.03 and R1.05 manual editions.
- installation-security: R1.05 OS list, Defender exceptions, IT security
2.0/3.0, LAPS, automatic configuration merge (jupgutl), PRM chapter,
port 34597; setup_check.ps1 gets -Version (default 1.05.00).
- data-access: L45 renumbered (new ch. 4 RESTful API), extended OPC UA
functions off by default, OPC UA methods (OPCUAC_METHOD_CALL2_DF),
Information Model Mapper, ServerConfig.xml in %TLS_SAV_PATH%.
- equipment: Modbus unchanged; IEC 104/61850 run as EQT managers
(eqtdbg, eqtfrcscn), IEC 61850 report control blocks, upgrade steps.
- Issues ISS-076..090; R1.05 notes on ISS-003/008/032/034/061;
progress and version-differences updated.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- New skill equipment with task modbus-station: line, station, scan type,
points and connected items by quick load, tested against CI Server's own
Modbus slave mirror (eqpmdcmem + eqpmdcslvtcp)
- CI-Eng-Sample: section PLC1, station CIENG_PLC with write/read-back
items, load/remove steps and mirror start/stop scripts
- ISS-024: the TCP slave answers Open Modbus/TCP, not RTU (closed)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>