b85a65250c R1.05 re-check: installation-security, data-access, equipment
Read-only re-check on the shared R1.05 test server plus a diff of the
R1.03 and R1.05 manual editions.

- installation-security: R1.05 OS list, Defender exceptions, IT security
  2.0/3.0, LAPS, automatic configuration merge (jupgutl), PRM chapter,
  port 34597; setup_check.ps1 gets -Version (default 1.05.00).
- data-access: L45 renumbered (new ch. 4 RESTful API), extended OPC UA
  functions off by default, OPC UA methods (OPCUAC_METHOD_CALL2_DF),
  Information Model Mapper, ServerConfig.xml in %TLS_SAV_PATH%.
- equipment: Modbus unchanged; IEC 104/61850 run as EQT managers
  (eqtdbg, eqtfrcscn), IEC 61850 report control blocks, upgrade steps.
- Issues ISS-076..090; R1.05 notes on ISS-003/008/032/034/061;
  progress and version-differences updated.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 18:26:35 +11:00
79c0bfa848 Record Modbus mirror start via tls\com after restart
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 17:26:17 +10:00
90058ffdef Add equipment skill and Modbus loopback station to CI-Eng-Sample
- New skill equipment with task modbus-station: line, station, scan type,
  points and connected items by quick load, tested against CI Server's own
  Modbus slave mirror (eqpmdcmem + eqpmdcslvtcp)
- CI-Eng-Sample: section PLC1, station CIENG_PLC with write/read-back
  items, load/remove steps and mirror start/stop scripts
- ISS-024: the TCP slave answers Open Modbus/TCP, not RTU (closed)

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 17:22:58 +10:00