@ -30,7 +30,7 @@ development system (see "Test system" in `progress.md`); they do not exist on ot
| ISS-009 | 2026-09-30 | Security Guide | DCOM port range printed as 20500–20550 in the firewall table but "2500–20550" in the OPC configuration table. Taken as a typo for 20500–20550. | open | Confirm on a system with IT security applied. | `knowledge/manuals/IM36K01C30-01EN.md` §4 |
| ISS-009 | 2026-09-30 | Security Guide | DCOM port range printed as 20500–20550 in the firewall table but "2500–20550" in the OPC configuration table. Taken as a typo for 20500–20550. | open | Confirm on a system with IT security applied. | `knowledge/manuals/IM36K01C30-01EN.md` §4 |
| ISS-010 | 2026-09-30 | ITEM (sub-items) | The Integrator sub-item adds value × seconds; setting `TIME_UNIT` = Hour made no difference (1 per second while the main item was 1). The Tutorial lists a time unit only for Rate-of-Change. | closed | 2026-09-30 (phase 5): IM 36K10C10 §3.2 and `itm.sup` answer it: the integral is divided by the **integration granule**`itm_int_secs` (label "Integration granule, sec.") in `itm.sup` — **system-wide**, installed value 1 (seconds); 60 = minutes, 3600 = hours. `TIME_UNIT` only applies to Rate-of-Change. Practiced 2026-09-30: set to 60 and restarted → `CI-Eng-Sample.PUMP1.RUNNING.RUN_SECONDS` rose exactly 1.0 in 60 s; restored to 1 (file identical to backup) → 8 in 8 s. Existing integrator values are not converted when the granule changes. Closed 2026-09-30 (confirmed by user). | `examples/CI-Eng-Sample/02b_sub_item_df.qli`; `knowledge/manuals/IM36K10G10-01EN.md` |
| ISS-010 | 2026-09-30 | ITEM (sub-items) | The Integrator sub-item adds value × seconds; setting `TIME_UNIT` = Hour made no difference (1 per second while the main item was 1). The Tutorial lists a time unit only for Rate-of-Change. | closed | 2026-09-30 (phase 5): IM 36K10C10 §3.2 and `itm.sup` answer it: the integral is divided by the **integration granule**`itm_int_secs` (label "Integration granule, sec.") in `itm.sup` — **system-wide**, installed value 1 (seconds); 60 = minutes, 3600 = hours. `TIME_UNIT` only applies to Rate-of-Change. Practiced 2026-09-30: set to 60 and restarted → `CI-Eng-Sample.PUMP1.RUNNING.RUN_SECONDS` rose exactly 1.0 in 60 s; restored to 1 (file identical to backup) → 8 in 8 s. Existing integrator values are not converted when the granule changes. Closed 2026-09-30 (confirmed by user). | `examples/CI-Eng-Sample/02b_sub_item_df.qli`; `knowledge/manuals/IM36K10G10-01EN.md` |
| ISS-011 | 2026-09-30 | ITEM (blocking) | A write to a blocked item with `itmval -p` (without `-o`) is silently ignored: no error message, value unchanged. | open | Check in phase 5 whether any status/return code signals this. | `.claude/skills/system-management/tasks/read-write-item.md` |
| ISS-011 | 2026-09-30 | ITEM (blocking) | A write to a blocked item with `itmval -p` (without `-o`) is silently ignored: no error message, value unchanged. | open | Tested 2026-10-01 (phase 12 issue review): nothing signals it. `itmval -p` on a blocked item exits with code 0 and prints nothing; `dssqld -m` on `ITEM_VAL.ITEM_VALUE` reports *Modified 1, Errors 0*; the value stays unchanged in both cases. Only the `blk` option flag (`itmval -g`) shows the item is blocked. Documented: check `blk` before writing. Close when the user confirms. | `.claude/skills/system-management/tasks/read-write-item.md` |
| ISS-012 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4.4 names the alarm item/display relation setup file `wfla_displays.sup`; the installed file is `wfla_display.sup` (no `s`). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo uses `wfla_display.sup`. | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/tasks/read-setup-file.md` |
| ISS-012 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4.4 names the alarm item/display relation setup file `wfla_displays.sup`; the installed file is `wfla_display.sup` (no `s`). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo uses `wfla_display.sup`. | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/tasks/read-setup-file.md` |
| ISS-013 | 2026-09-30 | CI Portal setup files | Installed values differ from the defaults stated in IM 36K10R10 §4.4: `wfla_display.sup``DUR_QUEUE_SIZE = 1000` (manual 500 kB); `wflgdi.sup``DUR_QUEUE_SIZE = 252` (manual 1000 kB); `wfla_display.sup` and `wflcdi.sup` set `TIMER_INTERVAL = 10` (manual: 1 s when not set). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo quotes the installed values as defaults. | `knowledge/manuals/IM36K10R10-01EN.md` §4 |
| ISS-013 | 2026-09-30 | CI Portal setup files | Installed values differ from the defaults stated in IM 36K10R10 §4.4: `wfla_display.sup``DUR_QUEUE_SIZE = 1000` (manual 500 kB); `wflgdi.sup``DUR_QUEUE_SIZE = 252` (manual 1000 kB); `wfla_display.sup` and `wflcdi.sup` set `TIMER_INTERVAL = 10` (manual: 1 s when not set). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo quotes the installed values as defaults. | `knowledge/manuals/IM36K10R10-01EN.md` §4 |
| ISS-014 | 2026-09-30 | CI Portal setup files | `jwuiisg.sup` has a *Security* tab (`SECURITY_ENABLED`, `CORS_ENTRY`, `HEADER_ENTRY`) that IM 36K10R10 §4.3 does not describe. | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). Documented from the file's own `!KEYWORD`/`!HELP` text. Installed CORS allows all origins (`allowedOrigins "*"`); tightening it is a site security decision. | `knowledge/manuals/IM36K10R10-01EN.md` §4.3 |
| ISS-014 | 2026-09-30 | CI Portal setup files | `jwuiisg.sup` has a *Security* tab (`SECURITY_ENABLED`, `CORS_ENTRY`, `HEADER_ENTRY`) that IM 36K10R10 §4.3 does not describe. | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). Documented from the file's own `!KEYWORD`/`!HELP` text. Installed CORS allows all origins (`allowedOrigins "*"`); tightening it is a site security decision. | `knowledge/manuals/IM36K10R10-01EN.md` §4.3 |
@ -39,12 +39,12 @@ development system (see "Test system" in `progress.md`); they do not exist on ot
| ISS-017 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4 says the logon method is the one user-interface setting normally changed, but the R1.03 `jwuiisg.sup`*Information* tab says the login method and login control settings have moved to `dssana.sup` (authentication and authorization). `dssana.sup` is not described in R10. | open | Installed software is the reference. 2026-09-30: `dssana.sup` ("Authentication and authorization setup") has tabs General, User Interfaces, Clients System Trust, Login control (`LOGIN_METHOD = <client>, <user interface>, <method>, …`), Active Directory, Single Sign On, Password rules, Logging. Manuals mentioning it: IM 36K01A50 (5×), 36K10C10 (6×), 36K10J40 (13×), 36K10L45 (2×), 36K10L50 (3×). Cover it in phase 5 (C10) and phase 13 (J40). 2026-09-30: login methods (Automatic, Manual CI Server, Manual OS, No, SSO, Deny) now summarized from C10 §2.2 in `knowledge/manuals/IM36K10C10-01EN.md`; AD/SSO details remain for J40. | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/SKILL.md` |
| ISS-017 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4 says the logon method is the one user-interface setting normally changed, but the R1.03 `jwuiisg.sup`*Information* tab says the login method and login control settings have moved to `dssana.sup` (authentication and authorization). `dssana.sup` is not described in R10. | open | Installed software is the reference. 2026-09-30: `dssana.sup` ("Authentication and authorization setup") has tabs General, User Interfaces, Clients System Trust, Login control (`LOGIN_METHOD = <client>, <user interface>, <method>, …`), Active Directory, Single Sign On, Password rules, Logging. Manuals mentioning it: IM 36K01A50 (5×), 36K10C10 (6×), 36K10J40 (13×), 36K10L45 (2×), 36K10L50 (3×). Cover it in phase 5 (C10) and phase 13 (J40). 2026-09-30: login methods (Automatic, Manual CI Server, Manual OS, No, SSO, Deny) now summarized from C10 §2.2 in `knowledge/manuals/IM36K10C10-01EN.md`; AD/SSO details remain for J40. | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/SKILL.md` |
| ISS-018 | 2026-09-30 | Authorization (`dssana.sup`) | IM 36K10C10 §2.2 says the *No* login method applies the user profile `FT_NO_LOGIN`; the installed `dssana.sup` names `CI_NO_LOGIN` (and `CI_NO_LOGIN_OPCUAS` for anonymous OPC UA) as the no-login profile. `USER_DF` on the test system has `CI_NO_LOGIN_OPCUAS` but no `CI_NO_LOGIN`. | open | Installed software is the reference: use `CI_NO_LOGIN`. Still to check: behaviour of a *No* login when that user does not exist (manual: no profile applied). Covered again in phase 13 (IM 36K10J40). | `knowledge/manuals/IM36K10C10-01EN.md` §2 |
| ISS-018 | 2026-09-30 | Authorization (`dssana.sup`) | IM 36K10C10 §2.2 says the *No* login method applies the user profile `FT_NO_LOGIN`; the installed `dssana.sup` names `CI_NO_LOGIN` (and `CI_NO_LOGIN_OPCUAS` for anonymous OPC UA) as the no-login profile. `USER_DF` on the test system has `CI_NO_LOGIN_OPCUAS` but no `CI_NO_LOGIN`. | open | Installed software is the reference: use `CI_NO_LOGIN`. Still to check: behaviour of a *No* login when that user does not exist (manual: no profile applied). Covered again in phase 13 (IM 36K10J40). | `knowledge/manuals/IM36K10C10-01EN.md` §2 |
| ISS-019 | 2026-09-30 | ITEM (string items) | Maximum string item length differs by source: IM 36K10C10 §3.3.4 says default 80, max 100; the Tutorial summary says up to 168 without audit; the data dictionary (`dssqld -f`) gives `ITEM_DF.STRING_LENGTH` range 1–200, default 80. | closed | Tested 2026-09-30 on CI-Eng-Sample (`dssqld -i`, `itmval -p/-g`, non-elevated): `STRING_LENGTH` 100, 168 and 200 load with or without `AUDIT_INFO`; 201 fails with `DSS-E-VAL_RANGE`. An item holds **length − 1** characters: a 99-character value in a length-100 item is stored with status 9 NORMAL; longer values are cut to length − 1 with status **12 OVERRANGED** (100 → 99, 200 → 199, 201 → 199). So the data dictionary (1–200) is right. Test items removed. Closed 2026-09-30 (confirmed by user). | `knowledge/manuals/IM36K10C10-01EN.md` §3; `knowledge/manuals/IM36K10G10-01EN.md` (items); `.claude/skills/item-engineering/SKILL.md` |
| ISS-019 | 2026-09-30 | ITEM (string items) | Maximum string item length differs by source: IM 36K10C10 §3.3.4 says default 80, max 100; the Tutorial summary says up to 168 without audit; the data dictionary (`dssqld -f`) gives `ITEM_DF.STRING_LENGTH` range 1–200, default 80. | closed | Tested 2026-09-30 on CI-Eng-Sample (`dssqld -i`, `itmval -p/-g`, non-elevated): `STRING_LENGTH` 100, 168 and 200 load with or without `AUDIT_INFO`; 201 fails with `DSS-E-VAL_RANGE`. An item holds **length − 1** characters: a 99-character value in a length-100 item is stored with status 9 NORMAL; longer values are cut to length − 1 with status **12 OVERRANGED** (100 → 99, 200 → 199, 201 → 199). So the data dictionary (1–200) is right. Test items removed. Closed 2026-09-30 (confirmed by user). | `knowledge/manuals/IM36K10C10-01EN.md` §3; `knowledge/manuals/IM36K10G10-01EN.md` (items); `.claude/skills/item-engineering/SKILL.md` |
| ISS-020 | 2026-09-30 | DATABASE (`dssqld`) | `dssqld -i "<long absolute path>\user.qli"` failed with `CRL-E-ENOENT` / `DSSQ-E-QLD_FILOPN`: the path in the message was cut after 79 characters (`…\73b3559a-12.`). A relative file name from the same folder works. Similar to the `intspawn` path limit (ISS-007). | open | Find the exact limit (79/80 characters?) and whether `-l` and `-e` paths are also cut. Until then: `cd` to the folder and use short relative names. | `.claude/skills/system-management/tasks/load-remove-records.md`; `.claude/skills/system-management/tasks/export-dataset.md` |
| ISS-020 | 2026-09-30 | DATABASE (`dssqld`) | `dssqld -i "<long absolute path>\user.qli"` failed with `CRL-E-ENOENT` / `DSSQ-E-QLD_FILOPN`: the path in the message was cut after 79 characters (`…\73b3559a-12.`). A relative file name from the same folder works. Similar to the `intspawn` path limit (ISS-007). | open | Tested 2026-10-01: the limit is **79 characters** for the whole path. An input file of 80–81 characters gives `DSSQ-E-Q_QLIEXT` (the name is cut, e.g. `….ql`), 85+ gives `CRL-E-ENOENT`. An `-e` output path of 80+ characters gives **no error**, but no file appears under the given name. Documented: keep paths ≤ 79 characters, or `cd` to the folder and use relative names. Close when the user confirms. | `.claude/skills/system-management/tasks/load-remove-records.md`; `.claude/skills/system-management/tasks/export-dataset.md` |
| ISS-021 | 2026-09-30 | EQUIPMENT (`eqpiostat`) | IM 36K10L40 §2 says `eqpiostat` stores hourly I/O statistics per station line in "history group STATION_STAT". On the test system `eqpiostat` runs (started by `equipment_start.cmd` on the host node) and `STATION_STAT` is a dataset, but `dssqld -e` returned 0 records, also with filters on `TIME_STAMP` and `STATION` (AID Modbus stations, which send requests). | open | Check whether records appear after a full hour with a communicating station, or whether the dataset is read another way (e.g. Engineering Module, report). | `knowledge/manuals/IM36K10L40-01EN.md` §2 |
| ISS-021 | 2026-09-30 | EQUIPMENT (`eqpiostat`) | IM 36K10L40 §2 says `eqpiostat` stores hourly I/O statistics per station line in "history group STATION_STAT". On the test system `eqpiostat` runs (started by `equipment_start.cmd` on the host node) and `STATION_STAT` is a dataset, but `dssqld -e` returned 0 records, also with filters on `TIME_STAMP` and `STATION` (AID Modbus stations, which send requests). | open | Check whether records appear after a full hour with a communicating station, or whether the dataset is read another way (e.g. Engineering Module, report). | `knowledge/manuals/IM36K10L40-01EN.md` §2 |
| ISS-022 | 2026-09-30 | ITEM (`itmval -f`) | `itmval -f <file> vs -n CI-Eng-Sample.TANK1.LEVEL` (IM 36K10L36 §1.4, write a restore command) crashes with a segmentation fault (bash) / access violation 0xC0000005 (PowerShell) and writes no file; also with `-l`. The manual's space-separated form `-n <inst> <unit> <tag>` is rejected with `FSL-E-NARG_ALL`. `itmval -g`/`-p` work. | open | Workaround: build restore lines from `itmval -g` output. Report to Yokogawa support if needed. | `knowledge/manuals/IM36K10L36-01EN.md` §3; `.claude/skills/system-management/tasks/read-write-item.md` |
| ISS-022 | 2026-09-30 | ITEM (`itmval -f`) | `itmval -f <file> vs -n CI-Eng-Sample.TANK1.LEVEL` (IM 36K10L36 §1.4, write a restore command) crashes with a segmentation fault (bash) / access violation 0xC0000005 (PowerShell) and writes no file; also with `-l`. The manual's space-separated form `-n <inst> <unit> <tag>` is rejected with `FSL-E-NARG_ALL`. `itmval -g`/`-p` work. | open | Workaround: build restore lines from `itmval -g` output. Report to Yokogawa support if needed. Retested 2026-10-01 with the documented syntax `itmval -f <file> <opts> -n <item>` (`<opts>` = letters from `vsqo`, e.g. `vs`): still a segmentation fault from bash and from `cmd`, in a short and a long folder, relative or absolute file name; `cmd` leaves an **empty** file. Treat `-f` as broken on R1.03.00. | `knowledge/manuals/IM36K10L36-01EN.md` §3; `.claude/skills/system-management/tasks/read-write-item.md` |
| ISS-023 | 2026-09-30 | ITEM / ITH (manual vs install) | Installed ITEM Service differs from IM 36K10L35/L36: `item_start.cmd` starts `itheix` (EVENT/ITEM storage, not described), aggregation `ithsag`/`ithrag`, two instances of each retrieve process, and `itmtim 100 1000 1 200 1` (five arguments, three documented); `itm.sup` item pool is 650000 KB (manual default 50000) and has `not_regained` (not described); `itheix.sup` has `max_sample_delay`, `max_samples_queued`, `max_open_files`. | closed | Closed 2026-09-30 (user decision: the installed software is the reference). Summaries describe the installed values. | `knowledge/manuals/IM36K10L35-01EN.md`; `knowledge/manuals/IM36K10L36-01EN.md` |
| ISS-023 | 2026-09-30 | ITEM / ITH (manual vs install) | Installed ITEM Service differs from IM 36K10L35/L36: `item_start.cmd` starts `itheix` (EVENT/ITEM storage, not described), aggregation `ithsag`/`ithrag`, two instances of each retrieve process, and `itmtim 100 1000 1 200 1` (five arguments, three documented); `itm.sup` item pool is 650000 KB (manual default 50000) and has `not_regained` (not described); `itheix.sup` has `max_sample_delay`, `max_samples_queued`, `max_open_files`. | closed | Closed 2026-09-30 (user decision: the installed software is the reference). Summaries describe the installed values. | `knowledge/manuals/IM36K10L35-01EN.md`; `knowledge/manuals/IM36K10L36-01EN.md` |
| ISS-024 | 2026-09-30 | EQUIPMENT (Modbus slave) | IM 36K10L41 §3.7 says `EQPMDCSLVTCP` waits for "MODBUS RTU requests via TCP/IP" and the CI Server master should use "MODBUS RTU via TCP/IP". A Modbus master station with `PROTOCOL = RTU` to `eqpmdcslvtcp` (port 5020) got no answer (`EQP-E-TCPRCVTMO`, 4 requests, 0 valid); with `Open Modbus/TCP` it worked at once. | closed | Closed 2026-09-30 (user decision: installed software is the reference). Use `Open Modbus/TCP` towards `eqpmdcslvtcp`. | `knowledge/manuals/IM36K10L41-01EN.md` §3.7; `.claude/skills/equipment/tasks/modbus-station.md` |
| ISS-024 | 2026-09-30 | EQUIPMENT (Modbus slave) | IM 36K10L41 §3.7 says `EQPMDCSLVTCP` waits for "MODBUS RTU requests via TCP/IP" and the CI Server master should use "MODBUS RTU via TCP/IP". A Modbus master station with `PROTOCOL = RTU` to `eqpmdcslvtcp` (port 5020) got no answer (`EQP-E-TCPRCVTMO`, 4 requests, 0 valid); with `Open Modbus/TCP` it worked at once. | closed | Closed 2026-09-30 (user decision: installed software is the reference). Use `Open Modbus/TCP` towards `eqpmdcslvtcp`. | `knowledge/manuals/IM36K10L41-01EN.md` §3.7; `.claude/skills/equipment/tasks/modbus-station.md` |
| ISS-025 | 2026-09-30 | PROCESS (PRINT) | A Traditional `PRINT "… 80 %, volume ", VOLUME;` logged `OPC-I-INFO, UMH Message Text Error: Message number 083A001B (… level reached 80 )`: the text is cut at the `%` and the rest is lost. Without `%` the full text is logged. | open | Avoid `%` in PRINT/ERROR text (sample uses "pct"). Check whether `%%` or `\%` gives a literal percent sign. | `knowledge/manuals/IM36K10P10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/traditional-class.md` |
| ISS-025 | 2026-09-30 | PROCESS (PRINT) | A Traditional `PRINT "… 80 %, volume ", VOLUME;` logged `OPC-I-INFO, UMH Message Text Error: Message number 083A001B (… level reached 80 )`: the text is cut at the `%` and the rest is lost. Without `%` the full text is logged. | open | Tested 2026-10-01 with a temporary class (removed): `PRINT "… 50 %% …"` logs `50 % …` correctly; `\%` and `%c` with 37 both give the *Message Text Error* and cut the text. Documented: write `%%`. Close when the user confirms. | `knowledge/manuals/IM36K10P10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/traditional-class.md` |
| ISS-026 | 2026-09-30 | PROCESS (`opc.sup`) | Installed PROCESS setup differs from IM 36K10L10 §2: `IMMED-EVENTS = NO` (manual: default on); `FLOW-CONTROL = 30,60` (manual 300/360 s); four executors `OPCEXE1`–`4` with fixed priority ranges (manual examples `OPCEXE01`…) and `opcdbg` still defaults to `OPCEXE`; keyword `VARTAB-SIZE` (manual `VARITAB-SIZE`); hidden keywords `FLDSEP`, `IGNEXI` not described; `ALARM-ITEMS` not set; class source file `opc_clssrc.dat` (manual `opc_clasrc.dat`); `opcini.sup` (licence line) not described. | open | Installed software is the reference (standing user decision); summary written from the installed files. Close when the user confirms. | `knowledge/manuals/IM36K10L10-01EN.md` §2, §5 |
| ISS-026 | 2026-09-30 | PROCESS (`opc.sup`) | Installed PROCESS setup differs from IM 36K10L10 §2: `IMMED-EVENTS = NO` (manual: default on); `FLOW-CONTROL = 30,60` (manual 300/360 s); four executors `OPCEXE1`–`4` with fixed priority ranges (manual examples `OPCEXE01`…) and `opcdbg` still defaults to `OPCEXE`; keyword `VARTAB-SIZE` (manual `VARITAB-SIZE`); hidden keywords `FLDSEP`, `IGNEXI` not described; `ALARM-ITEMS` not set; class source file `opc_clssrc.dat` (manual `opc_clasrc.dat`); `opcini.sup` (licence line) not described. | open | Installed software is the reference (standing user decision); summary written from the installed files. Close when the user confirms. | `knowledge/manuals/IM36K10L10-01EN.md` §2, §5 |
| ISS-027 | 2026-09-30 | PROCESS (`opcdbg`) | IM 36K10L10 §4 says the `opcdbg`*Dump classes/objects* files can be read by `dssqld`. The files have no `@LANGUAGE`/`@FIELDS`/`@<dataset>` headers (`NAME,"desc",prio` + source lines prefixed `- `); `dssqld -i` on the object dump gave `DSS-E-UNK_DS_NM, Unknown data set name`. | open | Use `dssqld -e CLASS_DF` / `OBJECT_DF` for transfers. Maybe an old tool reads the dump format; not found. | `knowledge/manuals/IM36K10L10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/opcdbg-checks.md` |
| ISS-027 | 2026-09-30 | PROCESS (`opcdbg`) | IM 36K10L10 §4 says the `opcdbg`*Dump classes/objects* files can be read by `dssqld`. The files have no `@LANGUAGE`/`@FIELDS`/`@<dataset>` headers (`NAME,"desc",prio` + source lines prefixed `- `); `dssqld -i` on the object dump gave `DSS-E-UNK_DS_NM, Unknown data set name`. | open | Use `dssqld -e CLASS_DF` / `OBJECT_DF` for transfers. Maybe an old tool reads the dump format; not found. | `knowledge/manuals/IM36K10L10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/opcdbg-checks.md` |
| ISS-028 | 2026-09-30 | PROCESS (class reset) | After recompiling a class with objects (`RESET_REQUIRED` 1), `dssqld -m` with `CLASS_DF``RESET` = 1 (also with `RESET_NODE` = host node name) is accepted with 0 errors but does not reset; `OBJECT_DF``RESET` = 1 is refused (`OPC-E-OBJ_RSTREQ`). `opcdbg` Classes → 8 *Reset class* works; it asks for a reset report file, which the manual does not list. | open | Use `opcdbg`. Still to try: `CLASS_RESET_COMMAND` (system-wide) and the Engineering Module's reset. | `.claude/skills/class-object-engineering/tasks/change-reset-class.md`; `knowledge/manuals/IM36K10L10-01EN.md` §4 |
| ISS-028 | 2026-09-30 | PROCESS (class reset) | After recompiling a class with objects (`RESET_REQUIRED` 1), `dssqld -m` with `CLASS_DF``RESET` = 1 (also with `RESET_NODE` = host node name) is accepted with 0 errors but does not reset; `OBJECT_DF``RESET` = 1 is refused (`OPC-E-OBJ_RSTREQ`). `opcdbg` Classes → 8 *Reset class* works; it asks for a reset report file, which the manual does not list. | open | Use `opcdbg`. Still to try: `CLASS_RESET_COMMAND` (system-wide) and the Engineering Module's reset. | `.claude/skills/class-object-engineering/tasks/change-reset-class.md`; `knowledge/manuals/IM36K10L10-01EN.md` §4 |
@ -108,7 +108,7 @@ SIGNAL VOLUME := FROM "<template item>[;<station>:<template point>]" MAKE
| Add | `x :+ 5;` / `x :+ -5;` | |
| Add | `x :+ 5;` / `x :+ -5;` | |
| IF | `IF c THEN … [ELSE …] ENDIF;` | Nestable |
| IF | `IF c THEN … [ELSE …] ENDIF;` | Nestable |
| TRIGGER | `TRIGGER 60;` / `TRIGGER CLASS alias;` | Run again after n s (last one wins); trigger a contained class |
| TRIGGER | `TRIGGER 60;` / `TRIGGER CLASS alias;` | Run again after n s (last one wins); trigger a contained class |
| PRINT | `PRINT "text ", x;` | To the message log when `PRINT = YES` (installed). A `%` in the text cuts the message (ISS-025) |
| PRINT | `PRINT "text ", x;` | To the message log when `PRINT = YES` (installed). A single `%` cuts the message; `%%` prints `%` (ISS-025) |
| ERROR | `ERROR "text";` | In a method: logs and stops this run. In the class prolog: **object creation is refused** and the text is returned (verified: `dssqld``.qlo` shows `OPC-E-INFO, <text>`) |
| ERROR | `ERROR "text";` | In a method: logs and stops this run. In the class prolog: **object creation is refused** and the text is returned (verified: `dssqld``.qlo` shows `OPC-E-INFO, <text>`) |
| STEP | `ENTRYCONDITION STEP = 2; … STEP := 3;` | Value of the control item; state machine between methods |
| STEP | `ENTRYCONDITION STEP = 2; … STEP := 3;` | Value of the control item; state machine between methods |