--- manual: IM 36K10L55-01EN title: Exchange Tool Engineering edition: 3rd Edition, Sep. 2023 version: R1.03 status: from docs only (needs CENTUM VP / an RGS node or CCC Prodigy data; not available on the test system) --- # Exchange Tool Engineering (R1.03) Two tools convert another system's engineering data into CI Server engineering data (a "publication" = generated quick load files plus `load.cmd`). Section numbers refer to the manual; Appendix 1 lists the supported CENTUM VP function blocks. ## 1. CI Exchange for CENTUM VP (§2) - Runs on an **RGS** (Remote Gateway Station: CI Server PC with a Vnet/IP card and driver from the medium, `VirtualProduct_CIServer_packageRxxx.zip`, option *installVirtProd*) that talks to CENTUM VP. *Single server*: the RGS is also the CI Core. *Non-single*: an upper CI Core gets the data from the RGS (MDUR). - Solutions: **RGS** (manual or automatic mode; automatic = the tool is embedded in the RGS, ENG HIS equalisation enabled, the RGS registered in the CENTUM VP project; publications generated after each CENTUM VP download) and **RGS with EAL** (external alarms; manual mode only). - Manual workflow: start the tool → create a project (*Single Server* ticked or not) → import CENTUM VP engineering data from the ENG HIS (and MTL file) → *Publish* (name pattern, folder, optional SQL tag filter such as `%PVI%`) → copy the publication folder to `C:\Program Files (x86)\Yokogawa\CIServer\Utility` → run its `load.cmd` on the RGS and/or CI Core (in an IT-security environment run `cmd.exe` *as different user* first). Automatic publications land in `%TLS_ALLUSERS_PATH%\lst\rgs\pub\`. - Output: items `
..` (e.g. `
.FIC001.PV`), points `:[]`, plus lines/stations, displays and symbols (displays only on the CI Core in non-single configurations). - Precautions (§2.15): refresh open LIST displays after a CENTUM VP online download; CI Server does not allow alarm limits on the wrong side of SV; short data gaps after Vnet scan changes or RDC switch-over; trends may lag after large downloads — reload displays, roll over the history group, tune scan types. - Installed: launcher `%TLS_ROOT_PATH%\tls\com\jwuiutl_ciexchange.cmd` (no RGS on the test system). ## 2. CI Exchange for Prodigy (§3) - For CCC Prodigy turbo-machinery controllers (antisurge, performance, speed). Input: the Modbus register list (`.csv`, from MakerPro) per controller; the station name and IP are entered in the tool. - Install: copy `Windows\EngineeringTools\CIExchange_Prodigy.zip` from the medium, extract to `C:\Program Files (x86)\Yokogawa\CIServer\Utility` (create the folder), run `CIExchange_Prodigy.cmd`. - Workflow: create project → import source configuration → generate publication → load it. Output: items `
.`, Modbus points `:[]`, and faceplates (title and engineering unit can be customised, §3.12.1).