# Issue register Open questions and problems found while building the repo. **Status:** open · investigating · closed Item and station names such as `AID.*` come from the author's own test project on the development system (see "Test system" in `progress.md`); they do not exist on other systems. ## How to close an issue 1. Confirm the answer with the user (practiced on the test system where possible). 2. Update **every file in the issue's "Update on close" column** with the answer. 3. Update the matching row in `knowledge/progress.md` (status and notes). 4. Set the issue to **closed** and write the resolution and date in "Next step / resolution". Keep closed issues in the table as history. ## Issues | ID | Date | Area | Issue | Status | Next step / resolution | Update on close | |---|---|---|---|---|---|---| | ISS-001 | 2026-09-30 | ITEM (`itmval`) | Writing an item with `itmval -p -n AID.WRPS.SIM.INFLOW -v 400` added the `uoff` option flag (options 0x…8a → 0x…8e). The flag stayed after writing the original value back. Meaning of `uoff` unknown; not found in the EN manuals by text search. | closed | 2026-09-30 (phase 5): IM 36K10C10 §3.5 gives the option bits: 1 blocked, 2 offline, **4 updated offline** (written by an application while offline), 8 acknowledged, **16 updated blocked**, 32 direct alarm, 64 delayed alarm. 0x8a = offline + acknowledged (+0x80, not documented); +4 = 0x8e, so `uoff` = updated offline and `ublk` = updated blocked. Matches all observations. Not yet found: how to clear the flags (probably on the next update from the station). Closed 2026-09-30 (confirmed by user). Earlier notes: writing internal sample items (`CI-Eng-Sample.*`, no station) does **not** set `uoff` (options stay 0x…88), so it is tied to station-connected items (the AID item was already `off`, its station not communicating). Still to find: meaning and how to clear it (ITEM Service IM 36K10L35/L36, Engineering Module I/O Processes IM 36K10C10). Revisit in phase 5 with a station item. 2026-09-30 later: unblocking a sample item left the flag `ublk` (after `blk` was cleared), so `u…` flags may mean "was …" (un-blocked / un-offline). Still unconfirmed. | `.claude/skills/system-management/tasks/read-write-item.md` (replace the `uoff` note under "Read the current value"); `knowledge/progress.md` row "Write an item with `itmval -p`" | | ISS-002 | 2026-09-30 | DATABASE (`dsschk`) | `dsschk -d ITEM_DF -v` (check only) exits 0 with no console output and nothing new in `umhlog.log`. Where results are reported is unknown. | closed | Closed 2026-09-30 (confirmed by user). 2026-09-30: `dsschk -e -v` prints a start/end line per dataset (228 checked, no problems) and logs to `umhlog.log`. Plain `dsschk` only compares copies between nodes, so it prints nothing on a single-node system. `ismchk` needs a database file name (usage: `ismchk data_base_name`), not run yet. | Create `.claude/skills/system-management/tasks/consistency-check.md` and add it to that skill's `SKILL.md`; `knowledge/manuals/IM36K10J10-01EN.md` §4.1.1 consistency tools (add where output goes); `knowledge/progress.md` row "Consistency check" | | ISS-003 | 2026-09-30 | DATABASE (`dssqld`) | Filtered export (`dssqld -e .qli`) failed with a guessed filter syntax (`@ITEM_DF`, `@FIELD`, `@SELECT`). | closed | Closed 2026-09-30 (confirmed by user). 2026-09-30: the quick load **data** format is now known and verified (`@LANGUAGE`, `@VERSION`, `@FIELDS`, `@`, quoted CSV records, `\` continuation, `!` comments; IM 36K10L45 §9.11). Filter syntax found (IM 36K10L50 §3.6) and practiced, awaiting confirmation: a file with `@SELECT`, then the filter in single quotes (strings in double quotes), then `@`; run `dssqld -e .qli`. `ITEM_HISTORY` returns nothing unless the filter names `ITEM_NAME` and a `SAMPLE_TIME` range (`SAMPLE_TIME > "dd-mm-yyyy hh:mm:ss" and SAMPLE_TIME < ...`). | `.claude/skills/system-management/tasks/export-dataset.md` section "Filtered exports"; `knowledge/manuals/IM36K10J10-01EN.md` §5.6 step 1; `knowledge/progress.md` row "Export a dataset" | | ISS-004 | 2026-09-30 | ITEM (`itmval`) | `itmval -g -a <1..5>` returns `ITM-E-WRONG_ATT` on `AID.WRPS.*` items, so reading limits is unproven. | closed | Closed 2026-09-30 (confirmed by user). On `CI-Eng-Sample.TANK1.LEVEL` (limits set) `-a 1..5` returned deadband 0, low 20, high 80, low-low 10, high-high 90. The error only occurs on items without limits. | `.claude/skills/system-management/tasks/read-write-item.md` (limits section); `knowledge/progress.md` row "Read an item with `itmval -g`" | | ISS-005 | 2026-09-30 | DATABASE (`dssqld`) | Loading `04_item_his_df.qli` straight after creating the storage group gave 2 errors once; three other runs were clean. Error text not captured. | open | Added a 5 s pause in `load.cmd`. If it happens again, capture `04_item_his_df.qlo`. | `examples/CI-Eng-Sample/load.cmd`; `.claude/skills/system-management/tasks/load-remove-records.md` | | ISS-006 | 2026-09-30 | HISTORY (`ithloahis`) | Samples dated before the start of the current storage unit were not stored (no error shown); samples after it were. Also, a new storage group stored nothing until CI Server was restarted. | closed | Closed 2026-10-01 (confirmed by user). Confirm with History Management (IM 36K10L20) in phase 9: how to load into older units, and whether a restart is really required. 2026-09-30 (phase 5): IM 36K10L35 §1.3/§5 explains the first part: event storage picks the unit by time stamp, never older than 60 units, and within the storage process's `gap_time` (ITHEEX/ITHEIX 2880 min) and, for EVENT/ITEM, `max_sample_delay` (ITHEIX 14400 min); older data needs earlier unit files (`hisdbg`, `hisrecover`, `isfrename`), `ithrecover -p` and a restart. Practice in phase 9. 2026-10-01 (phase 9, verified): (1) restart **is** required — `CIENG_SCAN10S` / `CIENG_AGG` loaded at 11:54 and `CIENG_EVENT` reloaded at 11:32 stored nothing until the 12:00 restart, then stored at once. (2) The first unit of a new Event/Item or Aggregation group is dated 2 days back (= `gap_time` 2880 min), but samples loaded into that pre-restart unit (11:50, 30-Sep) were still dropped; samples inside the active unit (12:02) and inside a unit closed by a forced rollover (12:03 into unit 3,1) were stored. So: samples older than the first unit opened since the restart are dropped silently. Loading older data would need `hisrecover` / `isfrename` / `ithrecover` (not practiced). Proposed close: documented in `load-history.md` and skill `history-management`. | `.claude/skills/system-management/tasks/load-history.md`; `examples/CI-Eng-Sample/README.md`; `knowledge/manuals/IM36K10J10-01EN.md` command-line tools | | ISS-007 | 2026-09-30 | INTEGRATION (monitoring) | `intdskmon` wrote 61.9 for a C: drive that is 61.9 % used / 38.1 % free, although the manual says it monitors the disk free space rate. `intspawn` did nothing when the command path was ~130 characters; a short path worked (limit unknown). | open | Confirm the disk value meaning and the path limit. | `.claude/skills/system-management/tasks/monitoring-processes.md`; `knowledge/manuals/IM36K10J10-01EN.md` §4.1.6; `examples/CI-Eng-Sample/monitoring/` | | ISS-008 | 2026-09-30 | ACCESS (ODBC server `odbsrv`) | `ci_start.log` on the test system shows `CppServerAPI::Run() failed: InitializeSslCtx(): SSL_CTX_use_certificate_chain_file() failed.` right after ACCESS Service starts. Which component and certificate is not known. | closed | Closed 2026-10-01 (confirmed by user): cause known, ODBC server left as is (not licensed/used on the test system). Identify in phase 7. 2026-10-01 (phase 7): cause found. The message comes from the ODBC server `odbsrv` (ACCESS Service, Simba): `odbsrv.sup` has `USESSL = YES` and `access_start.cmd` points it at `%TLS_ROOT_PATH%\tls\pki\odbsrv\SampleServerCertificate.pem` / `SampleServerKey.pem`, but that folder does not exist and no sample certificate is installed. `odbsrv` exits right after start (`DUR-W-REM_PROC, Process ODBSRV exited unexpectedly`), port 1583 does not listen. Fix (admin, only if ODBC is licensed and wanted): install a certificate + key there, or set `USESSL = NO`. Not applied. Close when the user confirms. | `.claude/skills/installation-security/tasks/setup-check.md`; `knowledge/manuals/IM36K10L45-01EN.md` §1 (done); `.claude/skills/data-access/tasks/access-checks.md` (done) | | ISS-009 | 2026-09-30 | Security Guide | DCOM port range printed as 20500–20550 in the firewall table but "2500–20550" in the OPC configuration table. Taken as a typo for 20500–20550. | closed | Confirm on a system with IT security applied. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K01C30-01EN.md` §4 | | ISS-010 | 2026-09-30 | ITEM (sub-items) | The Integrator sub-item adds value × seconds; setting `TIME_UNIT` = Hour made no difference (1 per second while the main item was 1). The Tutorial lists a time unit only for Rate-of-Change. | closed | 2026-09-30 (phase 5): IM 36K10C10 §3.2 and `itm.sup` answer it: the integral is divided by the **integration granule** `itm_int_secs` (label "Integration granule, sec.") in `itm.sup` — **system-wide**, installed value 1 (seconds); 60 = minutes, 3600 = hours. `TIME_UNIT` only applies to Rate-of-Change. Practiced 2026-09-30: set to 60 and restarted → `CI-Eng-Sample.PUMP1.RUNNING.RUN_SECONDS` rose exactly 1.0 in 60 s; restored to 1 (file identical to backup) → 8 in 8 s. Existing integrator values are not converted when the granule changes. Closed 2026-09-30 (confirmed by user). | `examples/CI-Eng-Sample/02b_sub_item_df.qli`; `knowledge/manuals/IM36K10G10-01EN.md` | | ISS-011 | 2026-09-30 | ITEM (blocking) | A write to a blocked item with `itmval -p` (without `-o`) is silently ignored: no error message, value unchanged. | closed | Tested 2026-10-01 (phase 12 issue review): nothing signals it. `itmval -p` on a blocked item exits with code 0 and prints nothing; `dssqld -m` on `ITEM_VAL.ITEM_VALUE` reports *Modified 1, Errors 0*; the value stays unchanged in both cases. Only the `blk` option flag (`itmval -g`) shows the item is blocked. Documented: check `blk` before writing. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/system-management/tasks/read-write-item.md` | | ISS-012 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4.4 names the alarm item/display relation setup file `wfla_displays.sup`; the installed file is `wfla_display.sup` (no `s`). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo uses `wfla_display.sup`. | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/tasks/read-setup-file.md` | | ISS-013 | 2026-09-30 | CI Portal setup files | Installed values differ from the defaults stated in IM 36K10R10 §4.4: `wfla_display.sup` `DUR_QUEUE_SIZE = 1000` (manual 500 kB); `wflgdi.sup` `DUR_QUEUE_SIZE = 252` (manual 1000 kB); `wfla_display.sup` and `wflcdi.sup` set `TIMER_INTERVAL = 10` (manual: 1 s when not set). | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). The repo quotes the installed values as defaults. | `knowledge/manuals/IM36K10R10-01EN.md` §4 | | ISS-014 | 2026-09-30 | CI Portal setup files | `jwuiisg.sup` has a *Security* tab (`SECURITY_ENABLED`, `CORS_ENTRY`, `HEADER_ENTRY`) that IM 36K10R10 §4.3 does not describe. | closed | Closed 2026-09-30 (user decision: the installed software and files are the reference). Documented from the file's own `!KEYWORD`/`!HELP` text. Installed CORS allows all origins (`allowedOrigins "*"`); tightening it is a site security decision. | `knowledge/manuals/IM36K10R10-01EN.md` §4.3 | | ISS-015 | 2026-09-30 | Setup File Editor | In `wfla_display.sup` the seven main keywords (`RELATION_LOCATION` … `TIMER_INTERVAL`) come before the only tab line `!TAB = Debug`. By IM 36K10R20 §3.1, keywords before the first `!TAB` are not shown, yet IM 36K10R10 §4.4.1 shows them on a *General* tab. What the editor really shows is unknown. | closed | Closed 2026-09-30 (checked in the Setup File Editor by the user; installed software is the reference). The editor shows keywords placed before the first `!TAB` on a **General** tab, followed by the defined tabs: `wfla_display.sup` shows *General* (all 7 fields, values as in the file) and *Debug*. The manual's statement that such keywords are ignored does not hold in R1.03. | `knowledge/manuals/IM36K10R20-01EN.md` §3; `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/tasks/change-setup-file.md` | | ISS-016 | 2026-09-30 | Setup File Editor | The R1.03 editor has features IM 36K10R20 §2 does not describe: a *Templates* tab next to *Setup Files*; a *Status* column in the file list (e.g. "Default"); *Undo Field* and *Reset Field* buttons on the edit form besides OK/Cancel/Help; a status bar with the selected file's description and the time. | closed | Installed software is the reference (user decision). 2026-09-30, tested on `wfla_display.sup` (`DUR_QUEUE_SIZE` 1000 → 2000): clicking **OK writes the file immediately** (only the active line changed; the manual says OK keeps the change in memory until Exit). Status becomes **Changed** when an active value differs from the file's `!DEFAULT` block; the changed field's label turns **blue**. *Reset Field* is enabled when the cursor is in a changed field; *Reset Field* + *OK* put the value back to the `!DEFAULT` value (2000 → 1000) and wrote the file at once (16:22:28); the rest of the file was unchanged. Still to find: what *Templates* holds and what *Undo Field* does. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10R20-01EN.md` §2; `.claude/skills/portal-setup/tasks/change-setup-file.md` | | ISS-017 | 2026-09-30 | CI Portal setup files | IM 36K10R10 §4 says the logon method is the one user-interface setting normally changed, but the R1.03 `jwuiisg.sup` *Information* tab says the login method and login control settings have moved to `dssana.sup` (authentication and authorization). `dssana.sup` is not described in R10. | closed | Installed software is the reference. 2026-09-30: `dssana.sup` ("Authentication and authorization setup") has tabs General, User Interfaces, Clients System Trust, Login control (`LOGIN_METHOD = , , , …`), Active Directory, Single Sign On, Password rules, Logging. Manuals mentioning it: IM 36K01A50 (5×), 36K10C10 (6×), 36K10J40 (13×), 36K10L45 (2×), 36K10L50 (3×). Cover it in phase 5 (C10) and phase 13 (J40). 2026-09-30: login methods (Automatic, Manual CI Server, Manual OS, No, SSO, Deny) now summarized from C10 §2.2 in `knowledge/manuals/IM36K10C10-01EN.md`; AD/SSO details remain for J40. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10R10-01EN.md` §4; `.claude/skills/portal-setup/SKILL.md` | | ISS-018 | 2026-09-30 | Authorization (`dssana.sup`) | IM 36K10C10 §2.2 says the *No* login method applies the user profile `FT_NO_LOGIN`; the installed `dssana.sup` names `CI_NO_LOGIN` (and `CI_NO_LOGIN_OPCUAS` for anonymous OPC UA) as the no-login profile. `USER_DF` on the test system has `CI_NO_LOGIN_OPCUAS` but no `CI_NO_LOGIN`. | open | Installed software is the reference: use `CI_NO_LOGIN`. Still to check: behaviour of a *No* login when that user does not exist (manual: no profile applied). Covered again in phase 13 (IM 36K10J40). | `knowledge/manuals/IM36K10C10-01EN.md` §2 | | ISS-019 | 2026-09-30 | ITEM (string items) | Maximum string item length differs by source: IM 36K10C10 §3.3.4 says default 80, max 100; the Tutorial summary says up to 168 without audit; the data dictionary (`dssqld -f`) gives `ITEM_DF.STRING_LENGTH` range 1–200, default 80. | closed | Tested 2026-09-30 on CI-Eng-Sample (`dssqld -i`, `itmval -p/-g`, non-elevated): `STRING_LENGTH` 100, 168 and 200 load with or without `AUDIT_INFO`; 201 fails with `DSS-E-VAL_RANGE`. An item holds **length − 1** characters: a 99-character value in a length-100 item is stored with status 9 NORMAL; longer values are cut to length − 1 with status **12 OVERRANGED** (100 → 99, 200 → 199, 201 → 199). So the data dictionary (1–200) is right. Test items removed. Closed 2026-09-30 (confirmed by user). | `knowledge/manuals/IM36K10C10-01EN.md` §3; `knowledge/manuals/IM36K10G10-01EN.md` (items); `.claude/skills/item-engineering/SKILL.md` | | ISS-020 | 2026-09-30 | DATABASE (`dssqld`) | `dssqld -i "\user.qli"` failed with `CRL-E-ENOENT` / `DSSQ-E-QLD_FILOPN`: the path in the message was cut after 79 characters (`…\73b3559a-12.`). A relative file name from the same folder works. Similar to the `intspawn` path limit (ISS-007). | closed | Tested 2026-10-01: the limit is **79 characters** for the whole path. An input file of 80–81 characters gives `DSSQ-E-Q_QLIEXT` (the name is cut, e.g. `….ql`), 85+ gives `CRL-E-ENOENT`. An `-e` output path of 80+ characters gives **no error**, but no file appears under the given name. Documented: keep paths ≤ 79 characters, or `cd` to the folder and use relative names. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/system-management/tasks/load-remove-records.md`; `.claude/skills/system-management/tasks/export-dataset.md` | | ISS-021 | 2026-09-30 | EQUIPMENT (`eqpiostat`) | IM 36K10L40 §2 says `eqpiostat` stores hourly I/O statistics per station line in "history group STATION_STAT". On the test system `eqpiostat` runs (started by `equipment_start.cmd` on the host node) and `STATION_STAT` is a dataset, but `dssqld -e` returned 0 records, also with filters on `TIME_STAMP` and `STATION` (AID Modbus stations, which send requests). | open | Check whether records appear after a full hour with a communicating station, or whether the dataset is read another way (e.g. Engineering Module, report). | `knowledge/manuals/IM36K10L40-01EN.md` §2 | | ISS-022 | 2026-09-30 | ITEM (`itmval -f`) | `itmval -f vs -n CI-Eng-Sample.TANK1.LEVEL` (IM 36K10L36 §1.4, write a restore command) crashes with a segmentation fault (bash) / access violation 0xC0000005 (PowerShell) and writes no file; also with `-l`. The manual's space-separated form `-n ` is rejected with `FSL-E-NARG_ALL`. `itmval -g`/`-p` work. | open | Workaround: build restore lines from `itmval -g` output. Report to Yokogawa support if needed. Retested 2026-10-01 with the documented syntax `itmval -f -n ` (`` = letters from `vsqo`, e.g. `vs`): still a segmentation fault from bash and from `cmd`, in a short and a long folder, relative or absolute file name; `cmd` leaves an **empty** file. Treat `-f` as broken on R1.03.00. | `knowledge/manuals/IM36K10L36-01EN.md` §3; `.claude/skills/system-management/tasks/read-write-item.md` | | ISS-023 | 2026-09-30 | ITEM / ITH (manual vs install) | Installed ITEM Service differs from IM 36K10L35/L36: `item_start.cmd` starts `itheix` (EVENT/ITEM storage, not described), aggregation `ithsag`/`ithrag`, two instances of each retrieve process, and `itmtim 100 1000 1 200 1` (five arguments, three documented); `itm.sup` item pool is 650000 KB (manual default 50000) and has `not_regained` (not described); `itheix.sup` has `max_sample_delay`, `max_samples_queued`, `max_open_files`. | closed | Closed 2026-09-30 (user decision: the installed software is the reference). Summaries describe the installed values. | `knowledge/manuals/IM36K10L35-01EN.md`; `knowledge/manuals/IM36K10L36-01EN.md` | | ISS-024 | 2026-09-30 | EQUIPMENT (Modbus slave) | IM 36K10L41 §3.7 says `EQPMDCSLVTCP` waits for "MODBUS RTU requests via TCP/IP" and the CI Server master should use "MODBUS RTU via TCP/IP". A Modbus master station with `PROTOCOL = RTU` to `eqpmdcslvtcp` (port 5020) got no answer (`EQP-E-TCPRCVTMO`, 4 requests, 0 valid); with `Open Modbus/TCP` it worked at once. | closed | Closed 2026-09-30 (user decision: installed software is the reference). Use `Open Modbus/TCP` towards `eqpmdcslvtcp`. | `knowledge/manuals/IM36K10L41-01EN.md` §3.7; `.claude/skills/equipment/tasks/modbus-station.md` | | ISS-025 | 2026-09-30 | PROCESS (PRINT) | A Traditional `PRINT "… 80 %, volume ", VOLUME;` logged `OPC-I-INFO, UMH Message Text Error: Message number 083A001B (… level reached 80 )`: the text is cut at the `%` and the rest is lost. Without `%` the full text is logged. | closed | Tested 2026-10-01 with a temporary class (removed): `PRINT "… 50 %% …"` logs `50 % …` correctly; `\%` and `%c` with 37 both give the *Message Text Error* and cut the text. Documented: write `%%`. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10P10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/traditional-class.md` | | ISS-026 | 2026-09-30 | PROCESS (`opc.sup`) | Installed PROCESS setup differs from IM 36K10L10 §2: `IMMED-EVENTS = NO` (manual: default on); `FLOW-CONTROL = 30,60` (manual 300/360 s); four executors `OPCEXE1`–`4` with fixed priority ranges (manual examples `OPCEXE01`…) and `opcdbg` still defaults to `OPCEXE`; keyword `VARTAB-SIZE` (manual `VARITAB-SIZE`); hidden keywords `FLDSEP`, `IGNEXI` not described; `ALARM-ITEMS` not set; class source file `opc_clssrc.dat` (manual `opc_clasrc.dat`); `opcini.sup` (licence line) not described. | closed | Installed software is the reference (standing user decision); summary written from the installed files. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10L10-01EN.md` §2, §5 | | ISS-027 | 2026-09-30 | PROCESS (`opcdbg`) | IM 36K10L10 §4 says the `opcdbg` *Dump classes/objects* files can be read by `dssqld`. The files have no `@LANGUAGE`/`@FIELDS`/`@` headers (`NAME,"desc",prio` + source lines prefixed `- `); `dssqld -i` on the object dump gave `DSS-E-UNK_DS_NM, Unknown data set name`. | open | Use `dssqld -e CLASS_DF` / `OBJECT_DF` for transfers. Maybe an old tool reads the dump format; not found. | `knowledge/manuals/IM36K10L10-01EN.md` §4; `.claude/skills/class-object-engineering/tasks/opcdbg-checks.md` | | ISS-028 | 2026-09-30 | PROCESS (class reset) | After recompiling a class with objects (`RESET_REQUIRED` 1), `dssqld -m` with `CLASS_DF` `RESET` = 1 (also with `RESET_NODE` = host node name) is accepted with 0 errors but does not reset; `OBJECT_DF` `RESET` = 1 is refused (`OPC-E-OBJ_RSTREQ`). `opcdbg` Classes → 8 *Reset class* works; it asks for a reset report file, which the manual does not list. | open | Use `opcdbg`. Still to try: `CLASS_RESET_COMMAND` (system-wide) and the Engineering Module's reset. | `.claude/skills/class-object-engineering/tasks/change-reset-class.md`; `knowledge/manuals/IM36K10L10-01EN.md` §4 | | ISS-029 | 2026-09-30 | PROCESS (Java) | IM 36K10P11 §10.4 says a new Java class must be reset before objects are added, otherwise the code does not take effect. A Java class inserted with `COMPILE` 1 by `dssqld` ran its first object correctly without any reset (twice, including a full sample reload). | open | Installed behaviour is the reference; keep "reset after changing a class that has objects". Check whether the Engineering Module path (compile without quick load) behaves differently. | `knowledge/manuals/IM36K10P11-01EN.md` §7; `.claude/skills/class-object-engineering/tasks/java-class.md` | | ISS-030 | 2026-10-01 | BUS (UMH tools) | `umhman` (hex code → text) crashes with redirected input (bash: segmentation fault 139 with CRLF input; PowerShell `Start-Process -RedirectStandardInput`: 0xC0000005); with an argument it only prompts. `umhtestprog` prints `UMH TEST UTILITY` and crashes (segmentation fault). `umhmsg 8010008` stops with `umh_panic: …umhmsg.exe, license expired` although other tools (`dssqld`, `itmval`) still worked at that time. | open | Try `umhman` interactively in a console; check `umhmsg` on a licensed system. Similar to ISS-022 (`itmval -f`). | `.claude/skills/system-management/tasks/bus-utilities.md`; `knowledge/manuals/IM36K10L30-01EN.md` §3 | | ISS-031 | 2026-10-01 | LICENCE (unlicensed node) | The unlicensed test node counts down about 1 hour of run time per CI Server start (`License time left` in `smd__LOW_smdsnp_general.log`, 3600 s → `*** license problem : 3 ***`); then `dssqld`/`itmval` stop with `license expired` and `ISF-F-LIC_PROB, DATABASE Service is not licensed`. A PC sleep pauses the count (start 17:25, ran out 09:52 next day). Restart of the CI Service resets it (verified 2026-10-01, back after ~45 s). | closed | Closed 2026-10-01 (confirmed by user): known limitation of the unlicensed test system, documented in system-check. Known limitation of the test system, documented in `system-check`. Plan tests in ≤ 1 h blocks. Close when the user confirms. | `.claude/skills/system-check/SKILL.md` §3 (done) | | ISS-032 | 2026-10-01 | ACCESS (OPC UA server node IDs) | IM 36K10L45 §10.3 shows CI Server node IDs (`{"nsid":"32"}`, `{"0":"Value","itnm":"ITEM1"}`) and the CI Server namespace `http://www.yokogawa.com/CI_Server/` (ns 3) but not which namespace the **entities** use. With that URI (or `urn::Yokogawa:CI_SERVER_OPC_UA_SERVER`) the client point was silently not monitored. Browsing (`OPCUAC_TAG_DF`) shows sections/items in **`urn:Yokogawa:CI_SERVER_OPC_UA_SERVER`**; with it `{"0":"Value","itnm":""}` and `{"0":"Value","nsid":""}` both work. IM 36K10E20 §2.2.6 also asks to enable `OPXUAS_USE_NAME_NODEIDS` and restart for CI client ↔ CI server; not needed on the test system. | closed | Closed 2026-10-01 (user decision: installed software is the reference). Installed software is the reference (standing user decision). Close when the user confirms. | `knowledge/manuals/IM36K10L45-01EN.md` §7 (done); `knowledge/manuals/IM36K10E20-01EN.md` §3 (done); `.claude/skills/data-access/tasks/opcua-client.md` (done) | | ISS-033 | 2026-10-01 | ACCESS (Engineering Module OPC UA point) | Tested by the user: the point form's *Browse path* stops at the item (`Objects/CI-Eng-Sample/TANK1/INFLOW`) and stores the item **object** `{"nsid":"548"}`; the point is not monitored (revised sampling interval 0, connected item status 13, *Last value*/*Data type* empty). Typing `{"0":"Value","itnm":"CI-Eng-Sample.TANK1.INFLOW"}` in *Node Id* fixed it (values followed at once). Browsing into an item that is OPC visible but not *Read* fails (`UncertainNotAllNodesAvailable`, `OPXC-E-BRW_NODE`). | open | Check whether the browse dialog can expand an item to `Value` (e.g. double-click); otherwise type the node ID. | `knowledge/manuals/IM36K10E20-01EN.md` §2 (done); `.claude/skills/data-access/tasks/opcua-client.md` §3 (done) | | ISS-034 | 2026-10-01 | ACCESS (OPC UA server setup) | Installed vs IM 36K10L45 §10.5–10.6: `ServerConfig.xml` enables certificate user tokens (`EnableCertificate true`, manual false) and offers no `None` endpoint (only Basic256Sha256 / Aes128_Sha256_RsaOaep / Aes256_Sha256_RsaPss with Sign or SignAndEncrypt); the `rejected` folder is created only at the first rejection; `opxuas.sup` uses `OPXUAS_DYNAMIC_SCANRATE` (manual `OPXUAS_USE_DYNAMIC_SCANRATE`) and has `OPXUAS_SET_HIGH_PRIO_15` (not described); `opxsys.sup` has `OPXDAS_SET_LOG_LEVEL` (not described). Also `dur.sup` adaptive queue entry `OPCEXE` while the installed executors are `OPCEXE1`–`4`. | closed | Closed 2026-10-01 (user decision: installed software is the reference). Installed software is the reference (standing user decision). Close when the user confirms. | `knowledge/manuals/IM36K10L45-01EN.md` §4, §7 (done); `knowledge/manuals/IM36K10L30-01EN.md` §8 (done) | | ISS-035 | 2026-10-01 | ALARM (`ALDPRT`) | `ALDPRT` is running and connected (`almdbg` 1 shows `Events-send-to` rising with each alarm), `aldprt.sup` sets no log destination (so per IM 36K10L15 §4.3 it should log via UMH) and `EVENTS` includes `alarm`/`ackn`, but no alarm line appears in `tls\log\umhlog.log` for the CI-Eng-Sample HIGH / HIGH HIGH / acknowledge events. No other log file changed. Cause unknown (UMH filtering? output only with `LOGUMH` set explicitly?). | open | Ask the user whether alarm lines were ever seen in the message log; possibly test `LOGUMH` (or `LOGSCN`) in `aldprt.sup` (admin, restart) in a later session. Low priority: history and overviews are not affected. | `.claude/skills/alarm-management/tasks/item-alarming.md` (last line); `knowledge/manuals/IM36K10L15-01EN.md` §8 | | ISS-036 | 2026-10-01 | ALARM (setup) | Installed vs manuals: `alh.sup` has `DB-JRNL = WAL` and `DB-SYNC = OFF`, not described in IM 36K10L15 §3.4; storage group `ALH` has lifetime **52 weeks** while IM 36K10C20 §A7 says the default is 2 days (may have been changed on this system earlier — unknown); `aldprt.sup` uses `TIMEFMT` where the manual text also writes `TIMFMT`. | closed | Installed software is the reference (standing user decision). Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10L15-01EN.md` §7, §8; `knowledge/manuals/IM36K10C20-01EN.md` §A7 | | ISS-037 | 2026-10-01 | ALARM (history fields) | `ALARM_CHRONO` records contain leftover or unreadable text: INFO events generated with `almdbg` 16 carry `INSTALL`/`UNIT`/`TAG`/`SUB` values from earlier events and non-ASCII bytes in `SOURCE`, `CATEGORY`, `CONDITION`; item events of `CI-Eng-Sample.TANK1.LEVEL` show `SUB` = `RoC` although the item has only the sub-item `MAX`. | open | Check whether the alarm overview shows the same (phase 10, needs a display). Treat these columns as unreliable for non-OPC events until then. | `.claude/skills/alarm-management/tasks/alarm-checks.md` §4 | | ISS-038 | 2026-10-01 | HISTORY (`ithloahis` + rollover) | An `ithloahis` sample that was dropped (dated 11:50, before the active unit) still became the **initial value** of the next unit: after a forced rollover at 12:05:26 `ITEM_HISTORY` shows `CI-Eng-Sample.TANK1.INFLOW` = 95 (`INITIAL_VALUE` 1) although the item's value was 112. History after loading old samples can therefore show a wrong value at the next rollover. | open | Accept as a caution (documented in `load-history.md`), or retest after a CI Server restart to see whether the wrong initial value persists. | `.claude/skills/system-management/tasks/load-history.md`; `knowledge/manuals/IM36K10C40-01EN.md` §3 | | ISS-039 | 2026-10-01 | HISTORY (setup) | Installed vs manuals: `hisdbg` menu runs to option 22 (manual text: `-1 - 10`, list to 22) and lists history types 4 (`STATION_STAT`) and 36 (`SYS_LOG`) not in IM 36K10L20 §3.1; `ithsag.sup` keyword `run_interval` (manual: *Heartbeat*) and `queue_size` 500 KB (manual default 200); the option-type table in IM 36K10L20 §3.1 is garbled in the PDF (observed: Scan/Time `1 1`, Event/Item `2 2`, Aggregation `4 4`). | closed | Installed software is the reference (standing user decision). Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10L20-01EN.md` §3; `knowledge/manuals/IM36K10C40-01EN.md` §2 | | ISS-040 | 2026-10-01 | HISTORY (aggregation) | Aggregation group `CIENG_AGG` (30 min + hour, `TANK1.LEVEL` max/min/avg) ran (`ithsag.log`: *Aggregation Completed*) but stored no values: retrieval gave `0x09 = ITM error` per period. `TANK1.LEVEL` was in `CIENG_EVENT` and `CIENG_SCAN10S`, both priority 0. Also `INTERPOLATION = "30 minutes"` is refused by `dssqld`; the installed name is `30Minutes`. | closed | Closed 2026-10-01 (confirmed by user). 2026-10-01 14:02: after `CIENG_SCAN10S` got `PRIORITY` 10, the 13:30–14:00 period stored max 77, min 33, avg 52.7, quality 1000 (`ithdbg` 20 and `dssqld` with `INTERPOLATION = "30Minutes"`). Cause: equal source priorities (C40 §2.1 says the highest-priority group is the source, but not that a tie gives nothing). Sample fixed (priority 10). The hourly value for 13:00–14:00 was not stored (first half had no source); not rechecked. Proposed close. | `.claude/skills/history-management/tasks/storage-groups.md` §4 (done); `knowledge/manuals/IM36K10C40-01EN.md` §3 (done); `examples/CI-Eng-Sample/03_his_group_df.qli`, `README.md` (done) | | ISS-041 | 2026-10-01 | GRAPHICS (HTML trend) | In the HTML display (`localhost:8080/mobileoperator/?d=CIENG_Tank`) the trend shows the pen legend `CI-Eng-Sample.TANK1.LEVEL [CIENG_SCAN10S]` and time axis but draws no line, although `ITEM_HISTORY` has 420 samples in the shown hour. Browser console: `Mismatch between number of labels (Time,CI-Eng-Sample.TANK1.LEVEL [CIENG_SCAN10S]) and number of columns in array (51)`. The trend has 4 further empty pens. 2026-10-01 later: the trend also had the property `chart.attribute[00]` connected to `TANK1.LEVEL` (added by mistake with the pen); the Operator Interface (desktop) showed *Short attribute name ( 61.0) is invalid*. After removing it the desktop trend draws the line, but the HTML trend still logs the mismatch error. | open | HTML only: try a trend with one pen (remove the empty ones) or a Micro Trend; check the HTML-supported trend properties (IM 36K10R30 §4.8.7); check whether the browser still uses a cached copy (`MO_CACHE_DISPLAYS` in `jwuiisg.sup`). | `.claude/skills/graphics/tasks/create-display.md`; `knowledge/manuals/IM36K10R30-01EN.md` §4 | | ISS-042 | 2026-10-01 | GRAPHICS (layouts) | Installed vs `Layouts.readme`: the factory layouts use status line item types `displayName`, `playbackIndicator` and `dateTime` and the commands `reload ` / `reload all`, none of which the readme lists (readme: `statusText`, `userName`, `progresBar`, `graphicsQueueLevel`, `connectionState`); the readme also writes `zooom` for the zoom command (factory files use `zoom`). | closed | Installed software is the reference (standing user decision). Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/graphics/tasks/layouts.md` §2 | | ISS-043 | 2026-10-01 | REPORT (system reports) | IM 36K10C30 App. 1.3 names two system reports `ALM_ATTS_CUR` and `ALM_ATRS_HIS`; the installed reports are `ALM_ATTRS_CUR` and `ALM_ATTRS_HIS`. The other 26 names match. | closed | Installed software is the reference (standing user decision). Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10C30-01EN.md` §8 (done) | | ISS-044 | 2026-10-01 | REPORT (scheduling) | Behaviour not in the manuals, found by quick load: a generation interval below 10 minutes is refused (`HIS-E-ROLLTOFAST`, the interval is the rollover of the report's storage group); a scheduled report cannot be deleted (`RPT-E-ACTIVE`) until `ACTIVATION_TIME` and `GENERATION_INTERVAL` are cleared; `CORRECT_DAYLIGHT` 0 counts intervals in UTC (06:00 set for January ran at 05:00 in October); a past activation time moves to the next slot - once (modify, past time within the lifetime) a single report labelled with the old time was generated, at insert with an older time none. | closed | Documented as verified behaviour; the one-off generation for a past activation time is not fully understood. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/reporting/tasks/define-reports.md` §1, §5, §6; `knowledge/manuals/IM36K10C30-01EN.md` §2; `examples/CI-Eng-Sample/83a_stop_report_df.qli`, `18_report_df.qli` | | ISS-045 | 2026-10-01 | REPORT (ad hoc from `dssqld`) | Generating ad hoc with `REPORT_DF.GENERATE` = 1 from `dssqld` (user `FULL AUTHORIZATION`) on a report without `ADHOC_DEST` logs `FSL-E-PRT_UNKUSER, Job submitted by unknown user (FULL AUTHORIZATION)` and `RPT-I-TRYPRINT` in `umhlog.log`; the generated report is stored normally. Phase 12 correction (2026-10-01): with `ADHOC_DEST` set the same error appears and nothing is printed (`CIENG_AUDIT`, `CIENG_TANK1` after a sample reload); the same report generated from the Engineering Module as `ADMIN` printed to `CIENG_FILE`. Related to the R1.03 known issue on report generation and default printers (IM 36K01A50, REPORT 1.11). | closed | Workaround documented: generate from the Engineering Module when printed output is needed (as `ADMIN` with destination `CIENG_FILE` it printed without errors, phases 11 and 12); runs from `dssqld` are stored but never printed, `ADHOC_DEST` does not help. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/reporting/tasks/define-reports.md` §2; `knowledge/manuals/IM36K10C30-01EN.md` §6 | | ISS-046 | 2026-10-01 | DATABASE (`dssqld` memo) | A memo field loaded from a file (`@""@`, IM 36K10L50 §3.10) fails with a relative name (`CRL-E-ENOENT`, the file is read on the server side) and with a long absolute path (`DSSG-E-STRBUFSMAL`, buffer 83); a short absolute path works. The manual gives no limits. | closed | Documented: use inline memos, or an absolute path ≤ 82 characters. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/system-management/tasks/dss-tools.md` §2; `knowledge/manuals/IM36K10L50-01EN.md` §4 | | ISS-047 | 2026-10-01 | REPORT (RQL manuals) | The manuals disagree: default `@WORKSPACE` 500 KB (IM 36K10R40 §2.2.2) vs 16 KB (IM 36K10C30 table 2.1-1, IM 36K10P20 §9.6); maximum `@WIDTH` 512 (R40, P20 §4) vs 5000 (P20 §9.6); `@FORMFEED` described with opposite meanings (C30: not 1 = form feed; P20: 0 = blank lines, default 1). Installed set-up files set `@workspace` explicitly (500 in `rptge1.rpt`, 100 in `rptgen.rpt`) and `@formfeed 0` for the interactive generator. | closed | Not tested (no printer); the set-up files make the defaults irrelevant in practice. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10R40-01EN.md` §2; `knowledge/manuals/IM36K10P20-01EN.md` §3 | | ISS-048 | 2026-10-01 | REPORT (ad-hoc parameters) | The prompt `[ITEM:NAME like "CI-Eng-Sample.TANK1.*"]Item for statistics:` (filter form as in IM 36K10C30 §2.1) gives an item tree browser in the Engineering Module generate dialog, but the tree shows all sections, not only `TANK1` items (checked by the user). | open | Try other filter forms (`%` wildcard, `SECTION = …`, `[ITEM:TAG="…"]`) and the display report component. | `.claude/skills/reporting/tasks/define-reports.md`; `knowledge/manuals/IM36K10C30-01EN.md` §2; `examples/CI-Eng-Sample/18_report_df.qli` comment | | ISS-049 | 2026-10-01 | AUDIT (item option *Audit trailing wanted*) | IM 36K10G10 ch. 9 and the classifier list (IM 36K10L25 App. 1, `ITEM.VALUE.MODIFY.`, `ITEM.HIGH-LIMIT…`) suggest item changes are audited per item when `AUDIT_INFO` = 1. On R1.03.00 none of the tested tools produced an `ITEM.*` event: `itmval -p` writes are not audited at all (with `AUDIT_INFO` 0 or 1); value writes through DSS (`dssqld -m ITEM_VAL`) and Engineering Module *Update value* are audited as dataset events (`ITEM_VAL`, `ITEM_VALUE` / `ITEM_VALUE_STR` / `STATUS`) for every item regardless of `AUDIT_INFO`. Operator-display writes and PROCESS writes (`opc.sup` `AUDIT = YES`, `COMPUTE` classifiers off by default) were not tested (no input field in the sample displays). | open | Test an operator value input on an item with `AUDIT_INFO` 1 (needs a display with an input field) and, if wanted, PROCESS with `AUDIT = YES`. | `.claude/skills/audit-trail/tasks/configure-audit.md` §1; `.claude/skills/audit-trail/tasks/read-audit-trail.md` §2; `knowledge/manuals/IM36K10L25-01EN.md` §3 | | ISS-050 | 2026-10-01 | AUDIT (classifier `STORAGE`) | Setting `AUDIT_EVENT_CLAS_DF.STORAGE` = 0 for `DATASET.NULL-ATTR.MODIFY.ENT-ENG-MOD` at 17:01:12 did not stop the next `dssqld -m ITEM_VAL` change from being stored (17:01:12.573). IM 36K10L25 §3.2 explains a per-process cache refreshed every `ECL_REFRESH` s (default 1800); the notifier here is `DSSSDA`, so the change should apply within 30 minutes. | closed | Re-tested: at 17:32:18 (after the 30-minute refresh) the same change was **not** stored, so the flag works with a delay. Set back to 1 at 17:32; the next change was still not stored (the cache works in both directions). Documented: allow up to `ECL_REFRESH` (1800 s) or restart CI Server. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `.claude/skills/audit-trail/tasks/configure-audit.md` §1; `knowledge/manuals/IM36K10L25-01EN.md` §3 | | ISS-051 | 2026-10-01 | AUDIT (manual vs installed) | Differences between IM 36K10L25 and R1.03.00: (1) App. 1 lists subject `F/T-SYSTEM`, the installed classifiers use `CI-SERVER` (logins) and also `EAL OPERATION` (subject and action) and source `VIA-OPC-UAS`, not in the manual; 463 classifiers installed. (2) App. 1 explanations of `SHELVE` and `UN-SHELVE` are swapped. (3) `QUESIZE`: manual default and maximum 200 kB, `adtsys.sup` help default 10 kB, minimum 10 (file sets 200). (4) `TIMEFMT` default: manual `DD/MM/YY hh:mm:ss.ppp`, `adtsys.sup` help without `.ppp`; `ADTLOG` output shows milliseconds (manual right). (5) `dssqld` changes are recorded with source `ENT-ENG-MOD`, not `QUICKLOAD`. (6) The selection expression language is not described in the manual; the compiler listing gives the words and operators (no `LIKE`). (7) `ADT` group lifetime 52 weeks on the test system vs 2 days default when `ADTSTO` creates it (§2.1.1). | closed | Documented in the L25 summary and the `audit-trail` skill. Close when the user confirms. Closed 2026-10-01 (confirmed by user). | `knowledge/manuals/IM36K10L25-01EN.md`; `.claude/skills/audit-trail/tasks/*.md` |