# R1.05 verification checklist Two kinds of R1.05 checks are open after the read-only re-check of 2026-10-08: - **Not tested:** the function is not available on the R1.05 test server, so it cannot be tested there at all. The content stays "from docs" and is marked **not tested** with the reason. Nothing to do until a suitable system exists. - **Awaiting user verification:** Claude could not run the step itself (refused as a remote command, needs an administrator, needs the GUI). Claude prepared the steps and expected results below; the user runs them on the server or in the GUI and sends the output or a screenshot, and Claude records the result in the task file and in `progress.md`. All steps below are read-only: they open forms or print information and save nothing. Close every form with *Cancel*. ## Not tested on the R1.05 test server | Area | Reason | Where marked | |---|---|---| | IT Security Tool (version 2.0 / 3.0), `CIX_` groups, `CTM_PROCESS`, LAPS, GPO import | Tool not installed; Windows Server 2025 is not supported by the tool | skill `installation-security`, C10/C30 summaries | | Vnet/IP drivers, VAGW Bossd | No Vnet/IP card; not supported on Server 2025 | skill `installation-security`, C10 summary | | Upgrade from R1.03/R1.04 with the automatic configuration merge (`jupgutl`, `-c` argument) | Fresh R1.05 install, no upgrade to observe; an upgrade test needs a separate machine | C10 summary, ISS-086 | | CI Server with PRM | No PRM | C10 summary, ISS-090 | | IEC 60870-5-104 and IEC 61850 (EQT managers, report control blocks, `eqtdbg`, `eqtfrcscn`) | No device and no EQT line on the server | skill `equipment`, L40/L41 summaries, ISS-076–079 | | OPC A&E `OPXAES_DIR_ALM`, OPC UA PubSub, imported information model | Needs another client/server or extra server instances | skill `data-access`, ISS-085 | ## Awaiting user verification ### V1. `eqpdbg` main info (skill `equipment`, L40 summary §3): **done 2026-10-08** Run by Claude over ssh at the user's request; output as expected (recorded in the L40 summary). On the R1.05 test server, in a normal command prompt: ``` eqpdbg 0 EQPMDC ``` Type `1` (Get main info), Enter, read the output, then `-1` (Exit). Expected: line type 107, the Modbus line(s) attached, scan interval (tick) in ms, number of slaves, line load %. Do not choose any other action number. Send a screenshot of the output. ### V2. Setup check script (skill `installation-security`, task `setup-check.md`): **done 2026-10-08** Run by Claude (temporary copy, deleted afterwards): 12 OK, 5 CHECK, 20 DIFF after fixing the firewall check (see `setup-check.md`). Copy `tools/setup_check.ps1` from this repo to a scratch folder on the server, run it in an **elevated** Windows PowerShell, then delete the copy: ``` powershell -NoProfile -ExecutionPolicy Bypass -File setup_check.ps1 ``` Expected (from the one-by-one checks of 2026-10-08): CI Server 1.05.00 OK; Windows Server 2025 Datacenter shown as not in the list; DIFF for firewall domain profile, Defender, automatic updates, defrag / component cleanup, page file, .NET 3.5, missing `CIX_` groups; CHECK lines for IT security. Send the result table (screenshot or text). ### V3. Engineering Module forms (skill `data-access`): **form definitions checked 2026-10-08** Claude has no GUI access to the server. Checked instead in the installed form definitions (`tls\wap\cfg`): the main menu has the *OPC UA Information Model Mapper* action (dataset `UASERVER_MAPPER_DF`); each user in the project tree has *Add API key* (dataset `API_KEYS_DF`); the OPC UA client point form has `READ_NODE_INFO` and `REBROWSE`; the method form has node ID type, parent object node ID, manual argument fields and no process-area field. Screenshots of the open forms are optional. In the Engineering Module on the server (log on as a user with engineering rights), open each form below, take a screenshot, and close it with *Cancel*: 1. *Tools › OPC UA Information Model Mapper*: the mapper window opens (shows *New Mapping*). 2. *Authorisation › Users*, any user: the *Add API Key* function exists (do not create a key). 3. An OPC UA client point form (*New* on an OPC UA station is enough to see it, then *Cancel*): the checkbox *Read additional node information* exists. 4. An OPC UA client method form: fields for node ID type, *Options* tab (parent object node ID) and *Arguments* tab; no process-area field. If no OPC UA client line exists on the server, steps 3–4 need one: skip them and say so. ### V4. Needs a decision first: CI-Eng-Sample on the R1.05 test server The sample tasks (Modbus mirror station, OPC UA loopback, items, alarms …) can only be re-tested on R1.05 by loading `CI-Eng-Sample` (all names `CIENG*`) onto the shared server. It adds records and starts extra equipment processes (`EQPCIENG` on port 5020), but touches no other project's records. Load only after the user approves; otherwise these tasks stay "verified on R1.03, files checked identical on R1.05".