- New skill equipment with task modbus-station: line, station, scan type, points and connected items by quick load, tested against CI Server's own Modbus slave mirror (eqpmdcmem + eqpmdcslvtcp) - CI-Eng-Sample: section PLC1, station CIENG_PLC with write/read-back items, load/remove steps and mirror start/stop scripts - ISS-024: the TCP slave answers Open Modbus/TCP, not RTU (closed) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
12 lines
143 B
Text
12 lines
143 B
Text
@LANGUAGE
|
|
ENGLISH
|
|
|
|
@VERSION
|
|
1.03.00
|
|
|
|
! Remove the CI-Eng-Sample Modbus line (after its stations)
|
|
@FIELDS
|
|
NAME
|
|
|
|
@MODBUS_LINE_DF
|
|
"CIENG_MB_LINE"
|