- New skill equipment with task modbus-station: line, station, scan type, points and connected items by quick load, tested against CI Server's own Modbus slave mirror (eqpmdcmem + eqpmdcslvtcp) - CI-Eng-Sample: section PLC1, station CIENG_PLC with write/read-back items, load/remove steps and mirror start/stop scripts - ISS-024: the TCP slave answers Open Modbus/TCP, not RTU (closed) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
14 lines
506 B
Text
14 lines
506 B
Text
@LANGUAGE
|
|
ENGLISH
|
|
|
|
@VERSION
|
|
1.03.00
|
|
|
|
! CI-Eng-Sample Modbus line (IM 36K10L41-01EN 3.6.1), CI Server R1.03.00
|
|
! Loading it creates tls\com\eqpcieng_start.cmd, _stop.cmd and tls\sup\eqpcieng.sup and
|
|
! starts equipment manager EQPCIENG (eqpmdc) after a few seconds. EQUIPMENT_NODE blank = local node.
|
|
@FIELDS
|
|
NAME,DESCRIPTION,LINE_TYPE,EQUIPMENT_MAN,HEART_BEAT,TIMEOUT,DEAD_TIME,REPEAT_CONNECTION_DELAY
|
|
|
|
@MODBUS_LINE_DF
|
|
"CIENG_MB_LINE","CI-Eng-Sample Modbus loopback line","TCP/IP","EQPCIENG",100,3000,30,10
|