Add phase 0-1 knowledge and system skills

Summarize the Release Information (known issues) and System
Design/Management manuals, add the system-check and system-management
skills practiced on the R1.03 test system, and add the progress tracker,
issue register and a CI-Eng-Sample placeholder. CLAUDE.md now requires a
version check, asks once per conversation whether to work directly or
prepare files only, and treats the manuals as development-only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Clio Liu 2026-09-30 13:07:37 +10:00
parent f919ccdcd7
commit 070e578129
12 changed files with 804 additions and 10 deletions

View file

@ -12,3 +12,8 @@ are not used for grouping; group tasks inside each skill instead:
The `description` in `SKILL.md` decides when Claude uses the skill. List the words users
will actually say.
Skills must work on any R1.03 system, so never use names from a particular system (items,
sections, stations, nodes). Write placeholders such as `<Section>.<Tag>` and, where an example
helps, use names from the sample project `CI-Eng-Sample` (`examples/CI-Eng-Sample/`).
Test-system evidence belongs in `knowledge/progress.md` and `knowledge/issues.md`.

View file

@ -0,0 +1,89 @@
---
name: system-check
description: >-
Read-only check of a CI Server machine, run before any CI Server work. Use when
the user asks which CI Server version is installed, whether CI Server is running, where it is
installed, whether time is synchronized, or before starting any task in another skill.
Also covers starting CI Server (needs administrator rights). Target version R1.03.
version: R1.03
source: IM 36K10J10-01EN §1.2, §1.4, §3.6, §3.7; practiced on the test system 2026-09-29/30
status: verified (2026-09-30)
---
# System check
Run this read-only check before any CI Server work. It changes nothing.
## 1. Installed version
PowerShell:
```powershell
$keys = @('HKLM:\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\*','HKLM:\SOFTWARE\WOW6432Node\Microsoft\Windows\CurrentVersion\Uninstall\*')
foreach ($k in $keys) { foreach ($i in (Get-ItemProperty $k -ErrorAction SilentlyContinue)) { if ($i.DisplayName -match 'CI Server') { "{0} | {1}" -f $i.DisplayName, $i.DisplayVersion } } }
```
Expected for this repo: `CI Server R1.03.00 (r10200M) | 1.03.00`. Anything else: warn the
user that the repo targets R1.03.
**From the running system** (preferred when CI Server is running): export the local node
dataset and read `VERSION_MAJOR`, `VERSION_MINOR`, `VERSION_PACK` (1, 3, 0 = R1.03.00).
```
dssqld -e local_node.qli -d LOCAL_NODE_DF -c -l local_node.lst
```
Run it in a scratch folder; it only reads. The same row shows the node name, node number and
licence state (`NAME`/`NODE_NAME` = `UNLICENCED` means no licence is registered).
`dssqld -f -l dict.lst` dumps the full data dictionary (all datasets and fields) if you need
to find another dataset.
**Per-component versions** (rewritten at every start): `%TLS_ALLUSERS_PATH%\lst\tls_versions.lst`,
one line per component: `<file>,<version>,<size>,<build date>`. On the test system all 110
lines read `R1.03.00`; a different version on some lines means a patch is installed.
**Message log**: `%TLS_LOG_PATH%\umhlog.log` holds CI Server messages
(`--> From: <PROCESS> (<node>) on <time>` then `<FAC>-<I|W|E>-<CODE>, <text>`). Read it after
starting CI Server to spot errors (e.g. `EQP-E-SLV_COM_BAD` = no communication with a
station). It can contain connection strings with passwords; never copy those into the repo.
## 2. Install paths (environment variables)
| Variable | Typical value | Holds |
|---|---|---|
| `TLS_ROOT_PATH` / `TLS_ITROOT_PATH` | `C:\Program Files (x86)\Yokogawa\CIServer` | Program: `tls\com` (start scripts), `tls\exe` (tools), `tls\sup` (setup files) |
| `TLS_ALLUSERS_PATH` | `C:\Users\Public\Yokogawa\tls` | Data root |
| `TLS_DAT_PATH` | `…\tls\dat` | Database |
| `TLS_HIS_PATH` | `…\tls\his` | History |
| `TLS_SAV_PATH` | `…\tls\sav` | Saved data |
| `TLS_LOG_PATH`, `TLS_LST_PATH` | `…\tls\log`, `…\tls\lst` | Logs and listings |
| `TLS_WAP_PATH` | `…\tls\wap` | Web application files |
`tls\com` and `tls\exe` are on `PATH`, so tools such as `dssqld` and `itmval` run from any
prompt. Setup files (`*.sup`) are plain text (CRLF); edit them with the Setup File Editor.
## 3. Is CI Server running?
- Windows service `StartCIServer` ("CI Service"), start type Manual on the test system.
- Running processes live under `…\Yokogawa\CIServer\tls\exe`. None running = CI Server stopped.
- Most tools (`dssqld`, `itmval`, …) need CI Server running.
- Starting it needs administrator rights (the service runs as `.\CIX_PROCESS`, binary
`tls\exe\ciserv.exe`). From a non-elevated shell `Start-Service StartCIServer` fails with
"Cannot open StartCIServer service". Start it from an elevated prompt:
`Start-Service StartCIServer` (or Services › CI Service › Start).
## 4. Time synchronization
`w32tm /query /status` and `w32tm /query /configuration` (Windows Time must be running).
Check the source matches the design (domain controller, NTP server or `NOSYNC` on Vnet/IP).
## Test system results (2026-09-29)
- Version R1.03.00 (r10200M). Matches the repo.
- Environment variables and folders as in the table; all tools and setup files named in
IM 36K10J10 are present except `tmtime` (a Vnet/IP station tool, not expected here).
- CI Service stopped on 2026-09-29; started 2026-09-30 from an elevated session. About 100
processes then run (e.g. `ciserv`, `dssman`, `itm`, `alm`, `his`, `rptgen`, `opcexe`,
`durm_udp`, `eqpmdc`, `eqpmqtt`, `wfl*`).
- `LOCAL_NODE_DF`: version 1.3.0 (R1.03.00), node 1, **UNLICENCED**, router type Endpoint.
- Windows Time running, source `time.windows.com`; synchronized on 2026-09-30 (stratum 5).

View file

@ -0,0 +1,27 @@
---
name: system-management
description: >-
CI Server R1.03 system management and command-line tools. Use when the user wants
to stop CI Server, export or
import dataset contents (dssqld), read or write item values (itmval), load or import history,
check database consistency (dsschk), monitor processes/CPU/disk/network, back up or migrate
a system, tune or debug CI Server, or plan a system layout (standalone, separate portal, HAC,
host-to-host, enterprise) or time synchronization. Source IM 36K10J10-01EN.
---
# System management (R1.03)
Background for this area: `knowledge/manuals/IM36K10J10-01EN.md`. Known issues:
`knowledge/manuals/IM36K01A50-01EN.md`.
Rules for every task:
- Run the `system-check` skill first (version must be R1.03).
- CI Server tools live in `%TLS_ROOT_PATH%\tls\exe` (on `PATH`). Run them in a scratch folder,
because they write output and listing files to the current directory.
- Starting/stopping CI Server and anything that writes to the system needs an elevated
(administrator) session and, in this conversation, the user's chosen way of working
(direct vs prepare only).
| Task | File | Status |
|---|---|---|
| Export dataset contents / dump the data dictionary | `tasks/export-dataset.md` | verified |

View file

@ -0,0 +1,52 @@
---
task: Export dataset contents with dssqld
version: R1.03
source: IM 36K10J10-01EN §2.9.2, §5.6; practiced on the test system 2026-09-30
status: verified
---
# Export dataset contents (dssqld)
Read-only. Needs CI Server running. Works from a normal or elevated prompt.
## Export a whole dataset
```
dssqld -e <output>.qli -d <DATASET> -c -l <listing>.lst
```
- `-d` dataset name (e.g. `ITEM_DF`, `STATUS_DF`, `LOCAL_NODE_DF`, `CLASS_DF`, `OBJECT_DF`).
- `-c` comma-separated output: first line is the field names, then one quoted row per record.
- `-l` writes the result summary to a listing file.
- `-a` also exports hidden fields.
The console (and listing) end with a summary; check `Errors` is 0:
```
Data set Recognized Exported Not found Errors
ITEM_DF 184 184 0 0
```
## Find datasets and fields
```
dssqld -f -l dict.lst
```
Dumps the data dictionary: every dataset with its description and fields (name, type, length,
description). Search it to find which dataset holds what, e.g. the version fields are in
`LOCAL_NODE_DF`, `HOST_NODE_DF` and `ENTERPRISE_SERVER_DF`.
## Useful datasets seen on R1.03
| Dataset | Contents |
|---|---|
| `LOCAL_NODE_DF` | This node: name, number, version (`VERSION_MAJOR/MINOR/PACK`), licence state |
| `ITEM_DF` | Item definitions: full name, section path, description, limits, format, type, station, I/O address |
| `STATUS_DF` | Item status definitions: name, number, alarm state, priority, colour, mnemonic (e.g. 9 = NORMAL) |
## Filtered exports
`dssqld -e <output> <filter>.qli` exports using a filter file with `@<DATASET>`, `@FIELD`
and `@SELECT` keywords (IM 36K10J10 §5.6). The exact filter syntax is **not yet verified**;
export the whole dataset and filter the CSV instead until it is.

View file

@ -1,28 +1,49 @@
# CI Server Engineering Assistant
You act as an experienced Yokogawa CI Server engineer. Users describe what they want to do
in CI Server; you do it (or guide them) using the knowledge in this repo.
in CI Server; you do it (or prepare it for them) using the knowledge in this repo.
- **Target version:** CI Server **R1.03**. Say so if a request depends on another release.
- **Language:** use the English (EN) manuals only.
## Before any CI Server work
1. **Confirm the software version.** This repo covers CI Server **R1.03** (R1.03.00).
Check the installed version first (skill `system-check`). If it is not R1.03,
tell the user before doing anything and point out which content may not apply.
2. **Ask how the user wants to work** — once per conversation, before the first action:
- **Direct**: you make changes in CI Server yourself (run tools, edit setup files, load data).
- **Prepare only**: you only read the system's files, generate new files in a location the
user chooses, and the user deploys them.
Remember the answer for the rest of the conversation. Reading files and read-only checks
are always allowed.
## Where to look, in order
1. **Skills**: `.claude/skills/<area>/`. There is one skill per CI Server area (e.g. Edit Module,
Alarm Management). `SKILL.md` is an index; open only the task file you need.
2. **Shared knowledge**: `knowledge/`. The document map, glossary, known issues and
system-wide concepts.
2. **Shared knowledge**: `knowledge/`. Manual summaries (`knowledge/manuals/`), known issues,
system-wide concepts and the document map.
3. **Examples**: `examples/`. Verified, working artifacts to copy and adapt.
4. **The manuals**: if the repo does not cover it, look it up in the EN PDFs. They are **not**
in this repo. Default location: `C:\Users\Public\Yokogawa\tls\doc\EN\`. Use
`knowledge/document-map.md` to find the right manual by IM number.
If the answer comes from the manuals rather than the repo, say so and name the manual
(IM number and section). Never guess CI Server behavior; say what you could not verify.
This repo is meant to be self-contained: the Yokogawa PDF manuals are only used while the
repo is being built, and users of the finished repo will not have them. If the repo does not
cover something, say so plainly instead of guessing CI Server behavior.
## Conventions
- Summarize manual content in your own words; never copy manual text into the repo.
- Cite sources (IM number + section) and the version in every knowledge or task file.
- Mark whether content is **verified** on a real system or **from docs** only.
- Before recommending a workflow, check `knowledge/manuals/IM36K01A50-01EN.md` (known issues).
- Never modify the manual folder.
- Skills use placeholders (`<Section>.<Tag>`) or names from the sample project `CI-Eng-Sample`
(`examples/CI-Eng-Sample/`), never names from a particular system. Names like `AID.*` in
`knowledge/progress.md` and `knowledge/issues.md` belong to the author's own test project and
will not exist on the user's system.
## Building the repo (development stage)
The manuals are at `C:\Users\Public\Yokogawa\tls\doc\EN\` on the development machine. Work
proceeds manual by manual in the order in `knowledge/progress.md`: summarize the manual into
`knowledge/manuals/`, practice each task on the test system, and record a task in a skill only
after the user confirms it works. Track status in `knowledge/progress.md`. Log open questions
and problems in `knowledge/issues.md`, each with the files to update once it is resolved.

View file

@ -0,0 +1,36 @@
# CI-Eng-Sample (placeholder)
**Status: planned, not built yet.** Nothing in this folder can be imported yet.
A small, invented sample project that anyone with this repo can load into a CI Server
**R1.03** test system. Skills use it for their examples, and every skill task can be practiced
and verified against the same known items on any machine.
## Planned contents
Built up phase by phase (see `knowledge/progress.md`):
| Phase | Adds |
|---|---|
| 5 Items and acquisition | Top-level section, sub-sections, template items, internal items (no PLC needed), items with alarm limits |
| 6 Classes and objects | A class and objects created from it |
| 8 Alarms | Alarm settings on sample items |
| 9 History | An item storage group |
| 10 Graphics | A display and symbol |
| 11 Reporting | A report |
## Planned files
| File | Purpose |
|---|---|
| `*.qli` | `dssqld` data files, one per dataset |
| `load.cmd` | Imports the data files in dependency order: template items → classes (compiled) → objects → remaining items (IM 36K10J10 §5.6) |
| `remove.cmd` | Removes the sample project from a system |
## Rules
- Test systems only. Loading writes to the CI Server database.
- Invented names only; no real plant or customer data.
- The top-level section name is still to be decided. Item names may not allow `-`, so it may
differ from the folder name (to be checked in phase 5).
- Every file notes the CI Server version it was built and tested on.

View file

@ -2,3 +2,7 @@
Working artifacts Claude can copy and adapt. Only add content that has been tested on a
real CI Server system; note the version and where it was tested.
| Folder | Contents |
|---|---|
| `CI-Eng-Sample/` | Sample project to import into a test system; skills use its names in examples (planned) |

View file

@ -5,4 +5,7 @@ that area's skill (`.claude/skills/<area>/reference/`).
| File | Contents |
|---|---|
| `issues.md` | Issue register: open questions and problems to come back to |
| `progress.md` | Working order of the manuals and status of every practiced task |
| `manuals/` | One summary per manual (`IM36K….md`), written in our own words |
| `document-map.md` | All EN manuals by IM number, with editions |

25
knowledge/issues.md Normal file
View file

@ -0,0 +1,25 @@
# Issue register
Open questions and problems found while building the repo.
**Status:** open · investigating · closed
Item and station names such as `AID.*` come from the author's own test project on the
development system (see "Test system" in `progress.md`); they do not exist on other systems.
## How to close an issue
1. Confirm the answer with the user (practiced on the test system where possible).
2. Update **every file in the issue's "Update on close" column** with the answer.
3. Update the matching row in `knowledge/progress.md` (status and notes).
4. Set the issue to **closed** and write the resolution and date in "Next step / resolution".
Keep closed issues in the table as history.
## Issues
| ID | Date | Area | Issue | Status | Next step / resolution | Update on close |
|---|---|---|---|---|---|---|
| ISS-001 | 2026-09-30 | ITEM (`itmval`) | Writing an item with `itmval -p -n AID.WRPS.SIM.INFLOW -v 400` added the `uoff` option flag (options 0x…8a → 0x…8e). The flag stayed after writing the original value back. Meaning of `uoff` unknown; not found in the EN manuals by text search. | open | Find what `uoff` means and how to clear it (ITEM Service IM 36K10L35/L36, Engineering Module I/O Processes IM 36K10C10). Until then, `itmval -p` stays "awaiting confirmation". | Create `.claude/skills/system-management/tasks/read-write-item.md` (with the `uoff` explanation) and add it to that skill's `SKILL.md` task table; `knowledge/progress.md` row "Write an item with `itmval -p`" |
| ISS-002 | 2026-09-30 | DATABASE (`dsschk`) | `dsschk -d ITEM_DF -v` (check only) exits 0 with no console output and nothing new in `umhlog.log`. Where results are reported is unknown. | open | Revisit with the Data Access / Data Set Service manuals; try without `-d`, or with `-e`. | Create `.claude/skills/system-management/tasks/consistency-check.md` and add it to that skill's `SKILL.md`; `knowledge/manuals/IM36K10J10-01EN.md` §4.1.1 consistency tools (add where output goes); `knowledge/progress.md` row "Consistency check" |
| ISS-003 | 2026-09-30 | DATABASE (`dssqld`) | Filtered export (`dssqld -e <out> <filter>.qli`) failed with a guessed filter syntax (`@ITEM_DF`, `@FIELD`, `@SELECT`). | open | Get the exact filter-file syntax from the Data Set Service manuals (IM 36K10L50 / P30). | `.claude/skills/system-management/tasks/export-dataset.md` section "Filtered exports"; `knowledge/manuals/IM36K10J10-01EN.md` §5.6 step 1; `knowledge/progress.md` row "Export a dataset" |
| ISS-004 | 2026-09-30 | ITEM (`itmval`) | `itmval -g -a <1..5>` returns `ITM-E-WRONG_ATT` on `AID.WRPS.*` items, so reading limits is unproven. | open | Retry on an item that has alarm limits configured (phase 8, alarms). | `.claude/skills/system-management/tasks/read-write-item.md` (limits section); `knowledge/progress.md` row "Read an item with `itmval -g`" |

View file

@ -0,0 +1,183 @@
---
manual: IM 36K01A50-01EN
title: CI Server Release Information
edition: 3rd Edition, Sep. 2023
version: R1.03
status: from docs
---
# Release Information: known issues and cautions (R1.03)
Known limitations and workarounds that the other manuals do not cover. Check this list
before recommending a workflow in any area. Section numbers refer to the manual.
## Platform and installation
| Area | Issue | What to do |
|---|---|---|
| Dual-redundant platform (1.1) | Without a Vnet/IP card, guest time sync by NTP makes host messages in the historical alarm overview show wrong timestamps. | Accept, or use Vnet/IP time sync. |
| Dual-redundant platform (1.1) | After both computers restart, the former standby may come up as *Guest OS (Isolated)*. | In the Redundancy Management Tool set Next Status to *Standby*, then restart that computer. |
| IT Security tool (1.3) | Remote Desktop to the CI Server may fail after applying IT Security if OS patch levels differ. | Patch both the server and the RDP client to the latest level. |
| IT Security tool (1.3) | Changing Windows region/language after applying IT Security causes problems. | Set region and language **before** applying IT Security; never change afterwards. |
| Windows (1.4) | Windows Server 2016 start menu may not refresh after install. | Restart after installing CI Server. |
| Windows (1.4) | CI Server started from the command line on Win10 / Server 2016 needs elevation. | Always use *Run as administrator*. |
| Windows (1.4) | Custom fonts can cause visual glitches in the Engineering and Edit modules. | Avoid custom fonts. |
| Install path (1.9) | The MELSEC EZSocket installer fails if CI Server is in a non-default path that contains spaces. | Non-default install paths must have no spaces. |
| Virtual machines (1.19) | Live migration, failover and shared-storage path switching lose acquired data/alarms; failover during engineering can corrupt the engineering data. | Migrate only when no engineering is in progress; keep engineering backups. |
| Virtual machines (1.19) | Serial-only drivers (Siemens 3964R, telemetry integration), Siemens SAPI-S7 and MELSEC are unavailable on VMs; many other drivers work over TCP/IP only. | Check driver support before choosing a VM. |
| Virtual machines (1.19) | Do not use VM replication; do not mix physical and virtual machines in HAC; only thin clients may RDP into a virtual CI Server. | Design accordingly. |
| Virtual machines (1.19) | The software medium must be mounted as an ISO on the VM (e.g. via Hyper-V Manager › Media › DVD Drive › Insert Disk). | Read "DVD drive" in the manuals as the mounted ISO drive. |
## Services
**ACCESS (1.5)**
- OPC classic on Win10 / Server 2016 / 2019 needs .NET 3.5. Install it from the Windows medium
(`DISM /Online /Enable-Feature /FeatureName:NetFx3 /All /LimitAccess /Source:<drive>:\sources\sxs`),
then re-run the OPC Core Components Redistributable in `%TLS_EXE_PATH%`.
- OPC AE: items in the tree root (no section) appear as `.NAME` and some clients can't use them
as alarm sources. Put alarm-source items inside a section.
**ALARM (1.6)**
- Shelving cannot restrict OPC AE items by status/type.
- Shelving more than 500 alarms can overflow the DURM queue; after a Portal–Core link loss,
restart the shelf overview.
**BUS (1.7)**
- Secure MDUR on Linux: create `/tls/pki` manually before configuring the secure connection.
**DATABASE (1.8)**
- With Active Directory login, up to ~15 s may pass between the login form closing and the
application appearing. Expected behavior.
**EQUIPMENT (1.9)**
- MELSEC iQ-R needs Mitsubishi EZSocket 4.4: uninstall older EZSocket first, then run
`RunInstaller` (as administrator) from `%TLS_ROOT_PATH%\tls\exe\EZSocketPcRedistributableInstaller`.
- IEC 61850: add the line, then the station (General tab: device IP; Options tab: domain prefix
and report object), then points. The element address is `<domain prefix><rest>`; the point
I/O address is only the part **after** the prefix (the prefix is added automatically).
Wrong delimiting means no reports/elements are created.
**PROCESS (1.10)**
- Java classes that access datasets must get the DSS session with `getDssSession()` (never
`Dss.createSession()` or `DssContext.getSession()`), must never close it, and must be
recompiled and reset after the change. Otherwise results are undefined
(e.g. `ADT-E-ECL_UNKNOWN` in the system log).
- When making items with SIGNALs, handle root-level items: if `SECTION` is empty use the tag
alone, else `SECTION || "." || tag`. Prefer automatic naming.
- Section-based SIGNAL creation does not support process area definitions.
**REPORT (1.11)**
- AD + printer management can make report generation fail (looks for the user's default
printer). Workaround: create a printer destination not bound to a device and set it as
the default destination in the AD user profile.
- Report features of Schemes take effect only after restarting the Engineering module.
**USER (1.12)**
- Remote Connect is for client machines **without** CI Server; don't install it on a CI Server.
- HTML5 displays cannot be validated via Remote Connect; engineer them on a CI Portal.
- HTML5 is a lightweight/mobile HMI with fewer components than Java displays (details in
Edit Module, IM 36K10C50). Use Google Chrome; other browsers may render differently.
- SSO leaves a landing page open that the user must close. SSO needs Active Directory, so
Windows only.
- `jwuiutl` over Remote Desktop is denied by default. To allow it: Setup File Editor ›
`dssana.sup` › *Login Control* tab › row *Client system name `<remote>`, Display and Symbol
Utility* › Login method = *No* › restart CI Server. Needed by CI Exchange (CENTUM VP /
Prodigy) load and conversion scripts.
- Remote Connect operator interface may fail to start (Java network read issue): retry, or
clear the Java cache (Java Control Panel › Temporary Internet files › Delete files).
- Auto-login is for server / CI Portal applications only, not Remote Connect.
- "Application blocked" for `.jnlp` over HTTPS is caused by the self-signed web server
certificate. Fix with a CA/domain-issued certificate (preferred) or add
`https://localhost:8443` to trusted sites (less safe).
- Web HMI display names are case sensitive.
- Custom Java components must be signed by Yokogawa before use.
- Edit module quirks: item properties editor Value field font too small; *Update
item/parameter* on the Attributes sheet ignores the first change (repeat it or use the
Actions sheet); a symbol custom property must not reuse an existing property name;
choosing *Open display* in an event's Action combo adds a duplicate event (delete it);
function components must stay inside the drawing area and must not be grouped.
- Same-size labels may render at slightly different sizes (Java anti-aliasing). Use *Apply
text smoothing* in the CI Portal setup file, or a non-integer zoom such as 99.999 %.
- HTML5 limitations: no login name in the status bar; frame border styles map imperfectly;
Windows display scaling must be 100 %; no rotation or column filters on alarm overview /
shelved alarm overview; transparency and margin properties are ignored.
## HMI, GIS and OPC UA
**HMI general (1.13)**
- Date/Time field with *editable* or *disable* set shows a black foreground in the operator
interface (correct in HTML).
- Up/down buttons differ in size between operator interface and HTML.
- With *Fit display*, tooltips and selection dialogs of trend / alarm overview are misplaced.
Uncheck *Zoom enabled* on those components, or design displays at the target resolution.
**GIS (1.14)**
- Click info is not shown for symbols built with a data bar. Use simple symbols as map markers.
- Don't use symbols containing alarm overview, trend or report components in GIS (high memory
in Chrome; alarm overview filters don't receive item names).
- Symbols/map layer may disappear or draw behind the map after long runs (Ctrl+wheel zoom
restores). In Chrome, disabling hardware acceleration fixes symbols drawn behind the map.
**OPC UA (1.15)**
- PubSub upload fails with *Internal error* if a published dataset has zero items. Remove or
revert those datasets.
- The datatype combo in PubSub Reader item mapping has no effect.
- Variables/properties of `CIAlarmConditionType` / `CISystemEventType` nodes can't be read
(`BadNotReadable`) or subscribed individually (`BadNotSupported`); subscribe to the alarm event.
- CI Core memory for external OPC UA clients: under 20,000 items no extra memory;
20,000–99,999 add 8 GB; 100,000–199,999 add 16 GB; beyond that add 8 GB per extra 100,000.
## Server Core / Portal (1.16)
- Secure DURM with an invalid certificate common name continues **unencrypted** (only logged).
After installing/refreshing certificates, check the message log that they were accepted.
- Remote Connect Engineering module is slow against a redundant CI Core. Use RDP to the Core,
or temporarily run the redundant platform in single mode.
- Several MQTT stations on one MQTT line with brokers unavailable can time out during offline
engineering. Use one station per line, or a temporary local broker.
- GIS component properties *Apply* increases Edit module memory each time; close the dialog
and display to recover.
- Object Selection dialog can hang the Edit module when a section has many objects (DSSSDA at
high CPU). Type the object name directly; to recover, stop that DSSSDA instance in
Performance Monitor, close the Edit module, restart CI Server.
- Enterprise Edit Module: shelved alarm overview shows nothing if added before the alarm
overview, on another layer, or with different alarm source locations. Add the alarm overview
first, same layer, same source locations.
- Alarm overview CI attributes: changing checkboxes on the Attributes tab can reorder the
Columns tab. Workaround: *Uncheck all* › Apply › re-check › Apply › reorder on Columns › Apply.
- Engineering module CI attribute names: pick *Add new record* or an existing name from the
drop-down; cancel the *Add new CI attribute* dialog if it appears unexpectedly.
- OPC UA alarm event type filters and alarm template settings that are in use can't be
deleted, and a same-named one on another station also becomes undeletable. Use unique names
per station; to recover, copy under a new name, repoint, then delete.
- EALs can't be edited in bulk in the Engineering module. Use `dssqld` on dataset
`EXTERNAL_ALARM_DF`.
- Retrieve from archive does not restore alarm attribute databases (alarms visible, attributes not).
- ODBC writes: Microsoft Access can't write to R1.03.00+; SQL Server Management Studio and
Excel via ODBC can't either. PowerShell and custom applications can (ODBC DSN
`CiSimbaClient`, e.g. `UPDATE ITEM_VAL SET ITEM_VALUE_STR=..., STATUS_NUMBER=... WHERE NAME=...`).
Alternatives: Excel Add-in, or `dssqld` on the Core/Portal.
- Acknowledging external alarms over ODBC: filter on `NAME` in `ALARM_CURRENT`
(e.g. `UPDATE ALARM_CURRENT SET ACK = 1 WHERE NAME = '<time>/<id>'`), not
`ITEM_NAME` / `ALARM_ORIG_TIME`.
## CI Exchange tools (1.17, 1.18)
- CENTUM VP and Prodigy tools use `jwuiutl`; over RDP, first allow it in `dssana.sup` (see USER).
- HTML5 conversion warnings about graphics outside the viewing area are harmless; move Generic
/ JavaScript function components into view and reconvert to silence them.
- *Illegal reflective access* Java warnings during load are harmless.
- Folders must not contain Japanese characters (project, CI Exchange project and publish
folders; `Load.cmd` fails with `UnicodeEncodeError`).
- `Unknown encoding 'ms932'` from `Load.cmd`: in the publish folder run `chcp 1252`, then `load.cmd`.
- Loading a publication overwrites VNET station settings (on scan, recover 10 s, slow 5 s,
medium 3 s, fast 1 s) and line device (`/dev/bk00`). Correct them manually afterwards.
- RGS with EAL: if both Vnet/IP buses to an FCS are cut, faceplates don't show OFFLINE and keep
old values. Set the alarm status manually, or map the Vnet communication status to an item.
- Unsupported controllers (e.g. GSGW, APCS) get stations created but no data. Exclude them in
the Import Wizard (RGS with EAL), or filter in the Publish Wizard, e.g.
`TYPE LIKE '%%' AND STATION <> 'FCS0256' AND STATION <> 'FCS0258'`; otherwise delete the
stations in the Engineering module.
- Tuning panel SUM is shown even when CENTUM integration is disabled. To reset to 0: disable
integration in CENTUM, then set SUM to 0 on the CI tuning panel.
- RGS collecting CENTUM alarms: 30 or more controllers needs +8 GB memory.

View file

@ -0,0 +1,263 @@
---
manual: IM 36K10J10-01EN
title: CI Server System Design/Management
edition: 3rd Edition, Sep. 2023
version: R1.03
status: from docs
---
# System Design / Management (R1.03)
How CI Server is built, how to choose a system layout, and how to run, back up, monitor,
tune and migrate it. Section numbers refer to the manual.
## 1. Fundamentals
**Three tiers (1.1)**
- **CI View**: the client HMI (Java or HTML5), on Windows PCs, tablets and phones.
- **CI Portal**: web server that sits between CI View and CI Core.
- **CI Core**: data server. Talks to field devices (EQUIPMENT drivers), processes real-time
data, manages alarms, stores history, exposes external interfaces.
**Node, services, processes (1.2)**
- One CI Server per machine; each is a **node**. The license is tied to the node.
- A node runs **services** (DATABASE, ITEM, ALARM, EQUIPMENT, REPORT, …). Which services start
depends on the license.
- Each service is made of **processes**; a process can have several **instances** (e.g. several
report generators, requests shared out by priority).
- Processes talk by **DUR messages**; each has a named queue, visible in Performance Monitor.
**Data model (1.3)**
- **Item**: the basic data point. Receives acquired values, sends operator/application writes
to the RTU, drives alarms, serves as class I/O and as dynamic properties of displays/symbols.
- **Section**: hierarchical folder for items (item full name `Section1.Section2.Tag`).
- **Object**: a set of items managed together; used by processing and linked to graphics.
- **External alarm (EAL)**: alarm from an external system received via the OPC UA client;
EAL settings are kept in sections.
- **Dataset**: table (rows/fields, like an RDB table) holding configuration, current data and
history. Users can add their own. Read by displays, symbols, classes, objects, reports and
external applications.
**Two layers (1.4)**: CI Portal services and CI Core services, on the same or separate machines.
| Service | CI Core | CI Portal |
|---|:-:|:-:|
| BUS | ✓ | ✓ |
| DATABASE | ✓ | ✓ |
| HISTORY, AUDIT, ITEM, EQUIPMENT, ALARM, PROCESS, REPORT, ACCESS | ✓ | |
| USER | | ✓ |
| INTEGRATION | ✓ | ✓ |
## 2. Inside CI Server
| Function | Service(s) | Summary |
|---|---|---|
| Data acquisition (2.1) | EQUIPMENT | Drivers for STARDOM FCX, Vnet/IP, Modbus, DNP3 and others. |
| Alarming (2.2) | ALARM | Detection (by CI Server or the RTU/PCS, with filters against chattering); notification to display, report, OPC AE/UA, sound, e-mail, printer; state and acknowledgement; stored in `ALARM_CURRENT` (current) and `ALARM_CHRONO` (history); analysis with ASPA. |
| Historization (2.3) | HISTORY | Storage groups made of storage units, one kind per data type: items (`ITEM_HISTORY`), alarms (`ALARM_CHRONO`), audit (`AUDIT_TRAIL`), system log (`SYS_LOG`), reports. |
| Symbol and processing (2.4) | PROCESS | Class → object → symbol (below). |
| Display (2.5) | USER | Displays contain symbols; appearance comes from layouts in an XML layouts file. User definitions set the initial display/layout; *Open display* actions name a display/layout. Defaults: display `main`, layout `default`. |
| Reporting (2.6) | REPORT | Configure in the Engineering module (query, schedule, trigger item, destination) → generate by schedule, trigger item or ad hoc → output via spool statement or destination (file, printer, application) → stored in history with a lifetime set by the storage group. |
| User authorization (2.7) | USER | Users belong to authorization groups; groups grant actions. Can be managed through a Windows domain (see Active Directory Integration, IM 36K10J40). |
| Multi-node (2.8) | BUS | **DURM** protocol between nodes: dynamic routing, best-line selection, auto-connect to the active HAC server, encryption and server certificates. |
| External interface (2.9) | ACCESS | ODBC (Simba server on the Core; optional license; the only route for non-Windows clients), OPC classic DA/AE/HDA (local network), OPC UA, remote database copy (mirror to external tables for complex queries; watch export size), Excel Add-in, command-line tools. |
**Class, object, symbol (2.4)**
- A **class** defines items, template items and processing; written in the *traditional*
language or Java. Traditional has no loops; Java classes cannot access datasets (no DSS).
- Class structure: `PROLOG` (local variables `VAR`, parameters `ATTRIBUTE`/`PROMPT`, items
`SIGNAL ... FROM <template> MAKE ...`) and `BODY` (`METHOD`s with `ENTRYCONDITION`s).
- An **object** is created from a class with parameter values; its items are created or removed
with it. Objects are triggered by the scheduler, trigger groups (intervals) or changes of
trigger signals. Traditional COMPUTE/FAST classes can also read/write datasets.
- A **symbol** can be linked to an object so item attributes drive colour, blinking, etc.
Symbols with no dynamic attributes need no object.
- Details: Class Description Language (IM 36K10P10 traditional, IM 36K10P11 Java).
## Command-line tools (2.3.1, 2.9.2)
| Tool | Purpose | Key usage |
|---|---|---|
| `dssqld` | Export / import / update / delete dataset contents; dump data dictionary | `-e <out> [<qli filter>] -d <dataset>` export (`-c` comma separated, `-a` include hidden fields); `-i <qli>` insert; `-m <qli>` update; `-r <qli>` delete; `-f` dump dictionary; `-l [<listing>]` log result; `-s <setup>` (default `dssqld.sup`). |
| `itmval` | Read/write current item data | `-g -n <item> [-a <attr>]` get (attr 1 deadband, 2 low, 3 high, 4 lowlow, 5 highhigh); `-p -n <item> [-v <value>] [-s <status>] [-q <quality>] [-o overwrite blocked] [-t [<date>] <time> [GMT\|LST]]` set; `-e` write to event history only (host node); `-f <file> <opts>` save a command file; `-l` use local node. |
| `ithloahis` | Load history from CSV into event-item / event-event storage groups | `-f <file> [-s <section prefix>] [-t GMT\|LST\|LCT] [-i update current value too] [-v] [-l]`. File is either `SCAN,<item1>,<item2>,...` then `<time>,<v1>,<v2>,...` (max 100 items), or `EVENT` then `<time>,<item>,<value>`. Times as date text or seconds since 1970. |
| `ithimport` | Import item history from another CI Server | `-l` list groups; `-s -g <from> [<to>]` show; `-i -g <from> [<to>] [-f <from time>] [-t <to time>] [-c <rename file>]` import. Rename file lines: `<old name>, <new name>`. |
| `alhimport` / `adtimport` | Import alarm / audit history from another CI Server | `-s` show, `-i` import, optional `-f` / `-t` time range. |
## 3. System design
**Standards to consider (3.1)**: ANSI/ISA-101 (HMI), EEMUA 191 and ISA 18.2 (alarms),
ISA-99 / IEC 62443 and ISO/IEC 17799 (security).
**Configurations (3.2)**
| Layout | When to use | Watch out for |
|---|---|---|
| **Simple**: one CI Core does everything | Local RTUs, a few tens of clients at most | Above ~10 clients, add a separate CI Portal |
| **Separate CI Portal** (Portal ↔ Core via DURM) | Many clients / load balancing; clients on untrusted networks; redundant Cores | Deploy display files to the Portals |
| **HAC** (high availability): ACTIVE + STANDBY Cores | Continuous operation required; large history that needs a live copy | Stable (ideally redundant) link between servers and to the island-detection network device; license Audit log if it is monitored |
| **Host to Host**: a client Core collects from server Cores via DURM | Reuse data at another site/level; RGS on Vnet/IP forwarding upward | Storage on the client Core can grow large |
| **Enterprise operation/engineering** | Share data and displays across Cores; standardize engineering (EES deploys configurations) | Needs deep knowledge of dataset dependencies |
- HAC: modes MANUAL / AUTO; functions monitoring (restart processes/server), watchdog (shuts
itself down if isolated), mirroring; options journaling (recommended on small systems) and
debug logging. Portals and OPC clients (via OPC tunneller) follow the active server. Dual
redundancy is standard; triple/quad need a special order (Tokuchu).
- Redundant networks: DNP3, Modbus, STARDOM FCX, Host-Host (DURM).
- Buffering and catch-up fill history gaps after outages: STARDOM FCX, DNP3, Host-Host.
**Sizing (3.4)**: estimate history disk size (storage group types and lifetimes) with the sizing
tool, and network load with the bandwidth sheets; include Vnet/IP load if connected.
**Long distance (3.5)**: advise on the WAN, but the network provider (or the client's own fibre)
owns its design.
**Time synchronization (3.6)**
- Why: Kerberos fails beyond 5 min skew; protocol timestamps; historians rejecting future data;
correlating events; cross-system scheduling.
- Terms: UTC/GMT; LST (local standard, no DST); LCT (local civil, with DST). CI Server tools
default to LCT unless noted.
- Adjust gently (slew, not step backwards). Forward jumps make aggregates too small, backward
jumps too large.
- Topologies: simple, cascade, star, tree (segment large/wide systems).
- Mechanisms:
- **(S)NTP / Windows Time**: domain members sync to the domain controller automatically;
workgroup machines need configuring. Registry
`HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Parameters\Type` = `NT5DS` (domain),
`NTP` (use `NtpServer`, DNS name), `NOSYNC`. Poll interval via
`Config\MinPollInterval` / `MaxPollInterval` (2^n seconds), or
`NtpClient\SpecialPollInterval` when `NtpServer` ends with `,0x1`.
- **DURECS**: external clock on a Core serial port (Wharton 482, Trimble GPS, Arbiter
1092/1093), set in `durecs.sup`.
- **DURUTL**: distributes the time master Core's clock to other nodes over DURM
(`durutl.sup`: interval, three deviation limits, two adjust steps, slave node list).
Resolution ~2 s; cannot sync a HAC standby.
- **DNP3**: CI Server as master writes time to outstations (STARDOM: set `TIM_SYNC_REQ` on
`SD_CDNP_*_OPEN`; CI side: station *Options* › time synchronization interval).
- **STARDOM FCX**: CI Server writes `FT_STime` at the station's interval (needs the FCX extension).
- **Vnet/IP**: the CENTUM domain master distributes network time; add an SNTP server to the
time group on BUS-1. On Vnet/IP stations Windows Time must be stopped/`NOSYNC`.
- Others with time sync: IEC 60870-5-101/102/103/104, FA-M3, MELSEC, Omron FINS, Allen
Bradley CIP, Bristol Babcock, Fisher ROC, TIE 870-5; ProSafe-PLC via start-up command file.
- Rules: one time master per machine; Vnet/IP overrides everything else; sync everything that
shares timestamped data; keep masters close; aim for under a few seconds deviation; plan
for time master failure.
- History event buffering: keep *Gap time* (default 2 days) and *Maximum sample delay*
(default 10 days) in `itheix.sup` / `itheex.sup` well above any expected time correction.
- Checks: `w32tm /query /configuration`, `w32tm /query /status`, `w32tm /resync /rediscover`;
`net time` (SMB, not NTP); `tmtime` on Vnet/IP stations.
**Hardening (3.7)**
- Windows Firewall on, with the exceptions CI Server needs; remove unused applications and
services.
- Install on a fixed, tested patch level; no automatic Windows updates; apply only
Yokogawa-evaluated patches.
- Antivirus with real-time scanning; exclude `C:\Users\Public\Yokogawa\tls\dat`, `…\tls\sav`,
`…\tls\his`.
- Recommended user groups: **Administrators** (everything), **Maintenance** (users, logs,
datasets), **Engineers** (engineering module: alarms, reports, graphics), **Operators**
(operator screens), **InternalProcess** (internal accounts, non-expiring passwords). The
manual's table maps each authorization (e.g. `ITEM_MODIFY_VALUE`, `REPORT_GENERATE_ADHOC`,
`USER_INSERT`) to these groups; in short, read rights go to all, engineering changes to
Administrators and Engineers, user management to Administrators and Maintenance.
## 4. Operation and maintenance
**Backup and recovery (4.1.1)**
- What to back up: the OS (~10 GB), CI Server software and setup files `%TLS_ROOT_PATH%\tls`
(~2 GB), database and display files `%TLS_ALLUSERS_PATH%` (~700 MB without history), and history.
- Plan for RTO/RPO, off-site copies, labelled and rotated media, and backup result reporting.
Recommended: disk first tier, tape second tier; centralized backup server; never back up over
the control network.
- Suggested schedule: full offline backup at version upgrades and periodic maintenance; full
after OS patches; weekly full; daily full or differential of the `tls` folder; archive history
weekly; export key datasets daily with `dssqld`.
- Don't change configuration during a backup. Use VSS for consistent online copies.
- Consistency tools: `ismchk <file>` / `ismkfr [-c] [-r] [-s] [-d] <file>` for ISAM files;
`dsschk [-d <dataset>] [-n <node>] [-e] [-r] [-v]` for replicated/duplicated datasets.
Repair: repeat `dsschk -r` until clean, then `dsschk -e`, then `dsschk -e -r` (maybe twice).
- Disaster recovery: restore system backup (or reinstall OS + CI Server + patches) → restore
`tls` configuration and database → verify.
- Retrieve archived history from the Engineering module (you can set its lifetime).
- Restore lost records: back up current data, build a `.qli` from the daily `dssqld` export,
import.
**Routine (4.1.2–4.1.5)**: OS patches, antivirus updates, user account housekeeping; watch
Windows and CI Server Performance Monitor, Windows event log, CI Server system log report and
audit trail report.
**Monitoring processes (4.1.6)** — INTEGRATION Service tools, each configured in its `.sup` file
and reporting status into items:
| Process | Monitors | How to start |
|---|---|---|
| `intmon` | process running; DURM node and channel status (can set slave items OFFLINE) | Uncomment its line in `%TLS_ROOT_PATH%\tls\com\integration_start.cmd` |
| `intcpumon` | CPU load (any perf counter) | `start /B /NORMAL %TLS_ROOT_PATH%\tls\exe\intcpumon -n intcpumon` then `durwfp -p intcpumon -t 10` |
| `intdskmon` | disk free space | same pattern with `intdskmon` |
| `inttcpmon` | TCP reachability (ping) of hosts | same pattern with `inttcpmon` |
| `intadtnot` | writes an AUDIT event from a script | `intadtnot -e A.B.C.D [-u user] [-t terminal] [-o old] [-v new]` |
| `intspawn` | runs a command on item value/status/option change, timer or node up/down (max 64 triggers) | `intspawn -n intspawn`, triggers in `intspawn.sup` |
**Problem handling (4.2)**: identify → investigate (performance monitors, logs, debug mode,
debug tools) → fix (memory size, queue size, load balancing, patch).
## 5. Implementation
**Engineering tools (5.1)**: License Request / Authorization wizards, Setup File Editor
(changes apply after the process restarts), Engineering module (Enterprise version for
enterprise systems), Edit module (displays and symbols), CI Exchange (import CENTUM VP
projects), Performance Monitor, Message log, ASPA, Excel Add-in, `hacw_hmi` (HAC management).
**CENTUM VP import (5.2)**: CI Exchange reads the VP project → produces import files and an
import command → run it → review scan times against Vnet/IP load.
**Designing classes and symbols (5.3)**
1. Create template items (analogue, digital, string…) in a common system section.
2. Group devices of the same type, define their inputs/outputs and common behavior in a class.
3. Decide which items the class creates; creating an object fails if its items already exist.
4. Group equipment with the same look into one symbol.
5. Sections in a class are relative to the object's section. Template items must exist before
objects are created (matters for migration scripts).
6. For performance, prioritize objects.
**Testing checklist (5.4)**: input validation (valid/invalid, boundaries, combinations,
defaults), outputs (destination, value, format, messages), interfaces (including offline
partners), scheduled tasks, UI (initial values, invalid/quick/concurrent operations,
usability), administrator tasks (backup, accounts, monitoring), performance and long-run
(leaks, disk), security (privileges), localization, regulations.
**Tuning (5.5.1)**
- Common memory: max processes 250 by default (`dur.sup`); keep free common memory above 10 %
and usage below 75 % (item pool size in `itm.sup`).
- Queues must not hold waiting requests; enlarge in each process's setup file. Objects running
too often: fix triggers/schedules, or add instances and priorities.
- Database: collisions under 250/s; entries under 80 % of max users (default 2K); max files
1,200. Set `-u` / `-f` in `database_start.cmd`; check with `ismdbg`.
**Debugging (5.5.2)**
- Enable debug/log per process in its setup file (`<process>.sup`, level 1–3, log size);
e.g. `alnmgr`, `eqp*` (`eqpfcx.sup`, `eqpmdc.sup`, or `eqpdbg` until restart), `hac`, `opc`
(PRINT statements to UMHLOG, on by default in `opc.sup`), `opxdac` (`opxsys.sup`),
`opxuac_mon`. Turn debug off afterwards (performance).
- Debug-mode launchers: `jwuipoi_debug` (operator interface), `jhmiset_debug` (Engineering
module), `jwuiged_debug` (Edit module), `fsuedit_debug` (Setup File Editor), `ftmoni_debug`
(Performance Monitor), `jwuitrd_debug` (Trend), `jwuiaan_debug` (ASPA),
`jtoolslic_debug` / `jtoolslicreq_debug` (license wizards).
- Debuggers: `dssxdb`, `dsschk`, `ismdbg` (DATABASE); `hisdbg`, `hasdbg` (HISTORY);
`itmdbg`, `ithdbg`, `ithrecover` (ITEM); `opxxdb` (ACCESS); `rptgen` interactive (REPORT);
`opcdbg` (PROCESS); `almdbg` (ALARM); `eqpdbg` (EQUIPMENT).
**Migration (5.6)**, e.g. from a demo-license system to the target system
1. Export master datasets with `dssqld -e`, using `.qli` filter files (`@<DATASET>`,
`@FIELD`, `@SELECT`) where needed: `AUTH_GROUP_DF`, `USER_DF`, `PRINTER_*_DF`,
`STATUS_DF`, `ALARM_ACK_DF`, `ALARM_AOI_DF`, communication `*_LINE_DF` / `*_STATION_DF` /
`*_POINT_DF`, `INSTALL_DF`, `UNIT_DF`, `ITEM_DF`, `HIS_GROUP_DF` (item storage groups
only), `CLASS_DF`, `OBJECT_DF`, `REPORT_DF`. Drop fields removed in the new release.
2. Re-apply setup file changes on the new system (setup file contents can change between releases).
3. Edit exports (e.g. node names in `PRINTER_TYPE_DF`, `*_LINE_DF`, `ITEM_DF`; set the
`COMPILE` flag to 1 in `CLASS_DF`), then import in dependency order:
template items → classes (compiled) → objects that create items → remaining items →
objects that create none. Check each `.qlo` listing for errors; reorder on relation errors.
4. History: copy `%TLS_HIS_PATH%` (except `has`) and `his_group.*` / `his_units.*` from
`%TLS_DAT_PATH%`; create the same item storage groups; `ithimport -g <group> -c <rename file>`;
`alhimport -i`. Alarm tag names cannot be renamed.

86
knowledge/progress.md Normal file
View file

@ -0,0 +1,86 @@
# Progress
Status of each manual and each practiced task. Update this file as work proceeds.
**Manual status:** not started · summarized · in practice · done
**Task status:** not practiced · practiced, awaiting confirmation · passed · not completed (see notes)
## Test system
Practice notes refer to the repo author's **development test system**, not to anything shipped
with this repo:
- CI Server R1.03.00, unlicensed, on the development machine.
- **AID** (e.g. `AID.WRPS.SIM.INFLOW`) is the author's own test project on that machine. It is
not in this repo and other systems will not have it. Item names here are evidence of what
was tested, not names to use elsewhere.
- Communication stations seen there (`WRPS_PLC`, `MODSIM_STATION`, `STN_MQTT`) belong to AID.
Shared, repeatable practice will use the sample project **CI-Eng-Sample**
(`examples/CI-Eng-Sample/`) once it exists.
## Manuals, in working order
| Phase | Manual | Title | Status |
|---|---|---|---|
| 0 | IM 36K01A50 | Release Information | summarized ([notes](manuals/IM36K01A50-01EN.md)) |
| 1 | IM 36K10J10 | System Design/Management | in practice, skill `system-management` ([notes](manuals/IM36K10J10-01EN.md)) |
| 2 | IM 36K01C10 | CI Server Setup | not started |
| 2 | IM 36K01C30 | Security Guide | not started |
| 3 | IM 36K10G10 | Tutorial | not started |
| 4 | IM 36K10R10 | CI Portal Setup | not started |
| 4 | IM 36K10R20 | Setup File Editor | not started |
| 5 | IM 36K10C10 | Engineering Module - I/O Processes | not started |
| 5 | IM 36K10L40 | EQUIPMENT Service - Utilities | not started |
| 5 | IM 36K10L41 | EQUIPMENT Service - Configuration | not started |
| 5 | IM 36K10L35 | ITEM Service - ITH | not started |
| 5 | IM 36K10L36 | ITEM Service - ITM | not started |
| 6 | IM 36K10L10 | Class/Object Engineering | not started |
| 6 | IM 36K10P10 | Class Description Language - Traditional | not started |
| 6 | IM 36K10P11 | Class Description Language - Java | not started |
| 7 | IM 36K10L55 | Exchange Tool Engineering | not started |
| 7 | IM 36K10L30 | BUS Service | not started |
| 7 | IM 36K10L45 | Data Access Engineering | not started |
| 7 | IM 36K10E20 | OPC Interface | not started |
| 8 | IM 36K10L15 | Alarm Management Engineering | not started |
| 8 | IM 36K10C20 | Engineering Module - Alarms | not started |
| 8 | IM 36K10E30 | Alarm System Performance Analysis | not started |
| 9 | IM 36K10L20 | History Management Engineering | not started |
| 9 | IM 36K10C40 | Engineering Module - Historical | not started |
| 10 | IM 36K10R30 | Graphic Display Setup | not started |
| 10 | IM 36K10C50 | Edit Module | not started |
| 10 | IM 36K10C60 | Advanced Operating Graphics | not started |
| 11 | IM 36K10L50 | Data Set Service Engineering | not started |
| 11 | IM 36K10P30 | Data Set Service Language | not started |
| 11 | IM 36K10P20 | Report Generation Language | not started |
| 11 | IM 36K10R40 | Report Server Setup | not started |
| 11 | IM 36K10C30 | Engineering Module - Reporting | not started |
| 11 | IM 36K10E10 | Excel Add-in | not started |
| 12 | IM 36K10L25 | Audit Trail Management | not started |
| 13 | IM 36K10J20 | High Availability Computing | not started (needs two servers) |
| 13 | IM 36K10J40 | Active Directory Integration | not started (needs a domain) |
| — | IM 36K01A10 / A20 / A30 | Read Me First, License, OSS terms | skipped (no engineering content) |
Order change after reading IM 36K10J10: its migration procedure (§5.6) shows the dependency
chain *communication lines/stations/points → installations/units → items (template items
first) → storage groups → classes → objects → reports*. So acquisition and items (phase 5)
now come before classes and objects (phase 6), and the other interfaces follow as phase 7.
## Tasks
| Manual | Task | Status | Notes |
|---|---|---|---|
| J10 | System check: version, paths, running state, time sync ([skill](../.claude/skills/system-check/SKILL.md)) | passed | Started CI Service elevated; live version R1.03.00; node UNLICENCED (expected). |
| J10 | Time sync check / configuration (`w32tm`, `durutl.sup`) | not practiced | Check only on this system; no Vnet/IP. |
| J10 | Export a dataset with `dssqld` ([task](../.claude/skills/system-management/tasks/export-dataset.md)) | passed | Filter-file syntax: [ISS-003](issues.md). |
| J10 | Import / update a dataset with `dssqld` | not practiced | Writes to the database; ask first. |
| J10 | Read an item with `itmval -g` | passed | Read `AID.WRPS.*` items. `-a 1..5` gave `ITM-E-WRONG_ATT` on an item without limits: [ISS-004](issues.md). |
| J10 | Write an item with `itmval -p` | practiced, awaiting confirmation | `AID.WRPS.SIM.INFLOW` 419.76 → 400 → 419.76. After the first write the item's options gained the `uoff` flag (0x8a → 0x8e), which stays after restoring the value. See [ISS-001](issues.md). |
| J10 | Read the message log (`tls\log\umhlog.log`) | passed | |
| J10 | Per-component version list (`tls\lst\tls_versions.lst`) | passed | |
| J10 | Load history from CSV with `ithloahis` | not practiced | Needs an item storage group. |
| J10 | Consistency check (`dsschk`, `ismchk`) | not completed | `dsschk -d ITEM_DF -v` exits 0 with no output and nothing new in the message log; See [ISS-002](issues.md). |
| J10 | Monitoring processes (`intmon`, `intcpumon`, `intdskmon`, `inttcpmon`, `intspawn`) | not practiced | Needs items to report into; better after phase 5. |
| J10 | Backup of `tls` folders | not practiced | Plan only; the actual backup tool is site-specific. |
| J10 | Migration between systems (§5.6) | not practiced | Needs engineered data; revisit after phase 6. |
| J10 | Tuning and debugging (setup files, `*_debug` launchers, debuggers) | not practiced | |