| IM 36K10P10-01EN | Class Description Language - Traditional | 3rd Edition, Sep. 2023 | R1.03 | from docs; PROLOG/ATTRIBUTE/PROMPT/ERROR, SIGNAL to an existing item and SIGNAL … FROM … MAKE, TRIGGER VALUE, the SECTION constant, transitional >=:, PRINT and runtime attribute change verified with CI-Eng-Sample class CIENG_TANK on 2026-09-30; everything else from docs |
Traditional PROCESS Service language (R1.03)
Summary in own words; section numbers refer to the manual. Engineering of classes and objects:
IM36K10L10-01EN.md and skill class-object-engineering.
1. Structure (§1, §11.1)
CLASS <name>; { name max 15 characters }
PROLOG { optional class prolog: runs when an object is CREATED }
<local declarations, CONTAINS, ATTRIBUTE, PROMPT, SIGNAL, statements>
BODY { needed only when there is a class prolog }
<global declarations: CONSTANT, VAR, TIMER, ALARM, ITEM, FOR>
METHOD <name>; { method name max 50 characters }
ENTRYCONDITION <cond>; { optional guard }
<local declarations>
PROLOG <statements> { optional: first run / after going on-line }
BODY <statements>
EPILOG <statements> { optional: when deactivated }
ENDMETHOD <name>;
ENDCLASS <name>;
- Comments:
{ … }, may span lines. - All methods of an active object run "simultaneously" (like tasks), not in order.
- Method parts by state: becoming active → prolog + body; staying active → body; becoming inactive (entry condition false or object off-line) → epilog (Table 1.3-1).
- Control item (optional, per object): blocked = methods suspended; off-line = stopped,
on-line again = start as new. Its value is
STEP(below). SEQUENCE/SUBSEQUENCEare old synonyms ofCLASS/METHOD; do not use.- Enterprise classes (Enterprise Engineering Module): extra
MAKEfieldsCREATE_ITEM,PUT_IN_HISTORY,ALARM_DETECTION=MASTER_ONLY/DELEGATE_ONLY/MASTER_AND_DELEGATE; ignored in local classes (§1.6).
2. Declarations (§2, §11.2)
| Declaration | Syntax (short) | Notes |
|---|---|---|
| Constant | CONSTANT a := 1, b := 2.5; |
Type from the expression |
| Variable | VAR x [INTEGER|FLOAT|STRING]; |
Default FLOAT; numbers convert, strings and numbers do not mix |
| Timer | TIMER t [TRIGGER]; |
Value = seconds left; t'status STOPPED / RUNNING / EXPIRED (initial EXPIRED). Assign seconds to start; 0 → EXPIRED. TRIGGER runs the object on expiry |
| Alarm | ALARM a [TRIGGER]; |
Value = alarm text, a'status NORMAL/A1/A2/A3 (OR ACKNOWLEDGE), a'priority. Needs ALARM-ITEMS in opc.sup (not set on the installed system) |
| Attribute | ATTRIBUTE n [OBJECT|CLASS] [INTEGER|FLOAT|STRING]; |
In class prolog only. OBJECT (default) = per object; CLASS = one value for all objects. Kept across restarts. Name max 15 |
| Prompt | PROMPT n QUERY "text"; / NOPROMPT path; |
Asks the value of an OBJECT attribute when an object is created. Declaration, not a statement |
| Containment | CONTAINS alias := other_class; |
Include another class; access alias.signal, nest a.b.signal |
| Signal | see §3 | In class prolog only |
| Item / For | FOR [node:]inst[.unit]; ITEM tag [TRIGGER type]; |
Fixed item names (first two section levels only); prefer SIGNAL |
Limits: identifiers 50 characters (class, attribute, signal, function names 15); string values max 255 characters.
3. Signals (§2.3, §11.2.8)
A signal links the object to an item whose name is computed when the object is created, so each object can use different items.
SIGNAL LEVEL := SECTION || ".LEVEL" TRIGGER VALUE; { existing item }
SIGNAL VOLUME := FROM "<template item>[;<station>:<template point>]" MAKE
"DESCRIPTION" EQUAL "text" "NAME" EQUAL "<new item name>" … ; { create the item }
- Types
INTEGER,FLOAT(default),STRINGafter the signal name. FROM … MAKE: copies the template item (and point) and overrides the listed fields; any field ofITEM_DF,SUB_ITEM_DF,ITEM_HIS_DFand the station'sPOINT_DFmay be used (e.g."STATION","POINT","IO_ADDRESS","ALARMING" EQUAL ON,"PROCESS_LIST" EQUAL "1,3"). Storage:"GROUP_NAME" EQUAL "<group>"followed by its storage fields ("STORE_VALUE","ON_VALUE_CHANGE"…); up to 4 groups; order matters. A template's own history membership is not copied.- Without
"NAME"the item is named<object>.[<containment path>.]<signal>and missing sections are created (verified: objectCI-Eng-Sample.TANK1.CALC, signalVOLUME→ itemCI-Eng-Sample.TANK1.CALC.VOLUME). Sub-items always need a name. - Items and sections the object created are deleted with the object (verified), unless the
object has
LEAVE_ITEMS; existing items are only unlinked. - An empty template name creates nothing: the signal stays unattached (
sig'attachedfalse). - Creating a point that already exists fails the object creation.
- Use
||to build names; a comma in a SIGNAL statement is read as a list separator. - Release notes: if the object sits at root level
SECTIONis empty — build names asIF SECTION = "" THEN tag ELSE SECTION || "." || tag; prefer automatic naming.
Trigger types (combine with |): VALUE, STATUS, OPTION, UPDATE, FIRST, PIT,
LIMIT, QUALITY.
Signal attributes (sig'attr; plain sig = value): VALUE, OLD_VALUE, STATUS,
CONTROL_STATUS, OPTION_STATUS (OPT_BLOCKED, OPT_OFF_LINE, … with bitwise operators),
MERGED_STATUS, ALARM_TYPE, ACKNOWLEDGED, the four limits, DEADBAND, QUALITY,
UPDATE_TIME, ID_*, SECTION, TAG, SUB, APPLICATION_INFO[i]/_SIZE/_FLAG,
LOCKED, ATTACHED. Which are writable differs between the manual's two tables (§2.3 vs
§11.2.8); value and limits are writable in both. To set value and status together use
SIG_UPDATE.
Object constants: NOW (GMT, float seconds), NODE, INSTALLATION, UNIT, SECTION
(object's section path — verified), TAG (object's tag), CLASS.
4. Statements and expressions (§3–5, §11.4–11.5, §11.7)
| Statement | Example | Notes |
|---|---|---|
| Assignment | x := 12; |
To variable, signal (writes the item), attribute, timer, alarm |
| Add | x :+ 5; / x :+ -5; |
|
| IF | IF c THEN … [ELSE …] ENDIF; |
Nestable |
| TRIGGER | TRIGGER 60; / TRIGGER CLASS alias; |
Run again after n s (last one wins); trigger a contained class |
PRINT "text ", x; |
To the message log when PRINT = YES (installed). A single % cuts the message; %% prints % (ISS-025) |
|
| ERROR | ERROR "text"; |
In a method: logs and stops this run. In the class prolog: object creation is refused and the text is returned (verified: dssqld .qlo shows OPC-E-INFO, <text>) |
| STEP | ENTRYCONDITION STEP = 2; … STEP := 3; |
Value of the control item; state machine between methods |
Operators, highest first: unary + -; NOT ~; * /; + -; string || and , (comma also
joins numbers); = <> =: <>:; < > <= >= <: >: <=: >=:; &; ^; |; AND; XOR; OR.
Transitional operators (=:, >=: …) are true only on the evaluation where the comparison
becomes true (edge detection) — verified: LEVEL >=: 80.0 fired for 85 and again for 81
after 70, not for 90 after 85. TRUE/ON and FALSE/OFF are the same.
IF TRIGGERED BY GROUP|SIGNAL|TIMER|TRIGGER|ALARM|ONCE tells why the object ran;
TRGSIG(sig), TRGTIM(t), TRGALM(a) name the exact source. A trigger group with interval
ONCE runs the object once when it is created, reset, its class reset, or PROCESS starts —
good for initialisation (ENTRYCONDITION TRIGGERED BY ONCE;).
Format strings for STRING(x, "fmt") (§11.7.4): 9 digits, 0 leading zeros, + sign,
. decimal point, EEEE exponent; dates (seconds since 1970) D DD DDD M MM MMM Y YY YYYY Hh Mm Ss P; \ escapes; %… C-style (%5.2f); empty = %g.
5. Built-in functions (§6.2, §11.6)
- Maths:
ABS,TRUNC,SQRT,POWER,EXP,LOG,LOG10,SIN/COS/TAN,ARC…,…HYP,RANDOM. - Time:
NOW,GMT,LCT(local time),ADDMONTH,DAYS. - Strings/conversion:
LENGTH,LEFT,MIDDLE,RIGHT,STRING,INTEGER,FLOAT. - Trigger info at trigger time:
TRGSIG_VALUE,TRGSIG_OLD_VALUE,TRGSIG_STATUS,TRGSIG_QUALITY,TRGSIG_UPDATE_TIME, limits,…_STR_VALUEetc. - Signal functions:
SIG_UPDATE(sig, value, status, add),SIG_UPDATE_TIME(…, time)(sends time to ITM; size its queue),SIG_OFFLINE(sig, on),SIG_LOCK,SIG_FORCE_ALARM_STATE,SIG_GETSUB(sig, avg, reset)(read and reset a sub-item in one step),SIG_GET_…/SIG_SET_…by attribute id (ids from Yokogawa).
User functions (§7): class named FUNCTIONS (no objects from it) with
FUNCTION [INTEGER|FLOAT|STRING|VOID] name; ARG a FLOAT, …; <CONSTANT/VAR>; <statements>; RETURN v; ENDFUNCTION name;. Max 10 arguments, passed by reference; a user function with a
built-in's name overrides it.
6. Datasets from a class (§12)
- Basic:
DSS_READ_STRING|INTEGER|FLOAT(dataset, record NAME, field, result)andDSS_UPDATE_STRING|INTEGER|FLOAT(…);result1 = OK. - Advanced:
id := DSS_OPEN(dataset, "F1, F2", "rudi", result)orDSS_OPEN_ALL;DSS_READ_EQUAL(id, name),DSS_READ_NEXT,DSS_SET_FILTER/DSS_REMOVE_FILTER,DSS_GET_…/DSS_PUT_…on the field buffer, thenDSS_UPDATE,DSS_INSERT,DSS_DELETE; alwaysDSS_CLOSE(id)(otherwise memory leaks).DSS_ERROR_LOG(on). - Only STRING, INTEGER, FLOAT data types are supported.
7. AGA gas calculations (§13)
AGA_INIT, AGA_COMP (composition), AGA_CALC, AGA_3_METER, AGA_CONE, AGA_PULSE,
AGA_8_GROSS, AGA_9_… (ultrasonic), AGA_R_… result getters, AGA_ERROR. Not practiced;
see the manual's §13.2 example if needed.
8. Examples in the manual (Appendix 1)
TWIN_UNIT_CONTR (STEP state machine with timers, transitional operators and limit changes)
and SENSOR/FLUID_VESSEL (containment). Reserved words: Appendix 2.