name: equipment
description: >-
CI Server R1.03 EQUIPMENT Service: lines, stations, scan types, I/O points and conversion
types. Use when the user wants to connect CI Server to a PLC, RTU or other device (Modbus
TCP/RTU, STARDOM FCX, FA-M3, DNP3, IEC 60870-5-104, IEC 61850, MQTT, OPC …), define or
remove a line, station, scan type or point, connect an item to an I/O address, set a station
off-scan or suppress outputs, add a station communication status item, run CI Server as a
Modbus slave, force a faster scan (eqpfrcscn), check equipment statistics or use the
equipment debugger (eqpdbg). Sources IM 36K10L40-01EN, IM 36K10L41-01EN, IM 36K10C10-01EN §4.1.
---
# Equipment (R1.03)
Background: `knowledge/manuals/IM36K10L41-01EN.md` (line types, station parameters,
conversion types, Modbus, driver table), `IM36K10L40-01EN.md` (forced scan, statistics,
`eqpdbg`), `IM36K10C10-01EN.md` §4.1 (Engineering Module forms).
Rules:
- Run the `system-check` skill first; follow the user's chosen way of working.
- Loading a line creates files in `tls\com` and `tls\sup` and starts an equipment manager;
removing it stops the manager and deletes them. Only do this on test systems or with the
user's approval.
- Outputs write to real devices: never write to a production station's output points without
the user's explicit approval.
- `eqpdbg`: only the read-only actions (see L40 summary) unless the user approves.
| Task | File | Status |
|---|---|---|
| Modbus TCP station by quick load: line, station, scan type, points, connected items; test, off-scan, remove | `tasks/modbus-station.md` | verified |
| CI Server as Modbus slave (mirror `eqpmdcmem` + `eqpmdcslvtcp`) | `tasks/modbus-station.md` §1 | verified (by hand and via start file after a restart) |
| Read-only equipment manager status with `eqpdbg` | `system-management` task `tuning-checks.md` | verified |
| Forced scan (`eqpfrcscn`), hourly statistics (`eqpiostat`) | L40 summary | from docs (statistics empty, ISS-021) |
| Other protocols | L41 summary §3.8–3.40 | from docs (no hardware) |