ci-server-engineer/.claude/skills/equipment/SKILL.md
cliu 90058ffdef Add equipment skill and Modbus loopback station to CI-Eng-Sample
- New skill equipment with task modbus-station: line, station, scan type,
  points and connected items by quick load, tested against CI Server's own
  Modbus slave mirror (eqpmdcmem + eqpmdcslvtcp)
- CI-Eng-Sample: section PLC1, station CIENG_PLC with write/read-back
  items, load/remove steps and mirror start/stop scripts
- ISS-024: the TCP slave answers Open Modbus/TCP, not RTU (closed)

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 17:22:58 +10:00

2 KiB
Raw Blame History

name description
equipment CI Server R1.03 EQUIPMENT Service: lines, stations, scan types, I/O points and conversion types. Use when the user wants to connect CI Server to a PLC, RTU or other device (Modbus TCP/RTU, STARDOM FCX, FA-M3, DNP3, IEC 60870-5-104, IEC 61850, MQTT, OPC …), define or remove a line, station, scan type or point, connect an item to an I/O address, set a station off-scan or suppress outputs, add a station communication status item, run CI Server as a Modbus slave, force a faster scan (eqpfrcscn), check equipment statistics or use the equipment debugger (eqpdbg). Sources IM 36K10L40-01EN, IM 36K10L41-01EN, IM 36K10C10-01EN §4.1.

Equipment (R1.03)

Background: knowledge/manuals/IM36K10L41-01EN.md (line types, station parameters, conversion types, Modbus, driver table), IM36K10L40-01EN.md (forced scan, statistics, eqpdbg), IM36K10C10-01EN.md §4.1 (Engineering Module forms).

Rules:

  • Run the system-check skill first; follow the user's chosen way of working.
  • Loading a line creates files in tls\com and tls\sup and starts an equipment manager; removing it stops the manager and deletes them. Only do this on test systems or with the user's approval.
  • Outputs write to real devices: never write to a production station's output points without the user's explicit approval.
  • eqpdbg: only the read-only actions (see L40 summary) unless the user approves.
Task File Status
Modbus TCP station by quick load: line, station, scan type, points, connected items; test, off-scan, remove tasks/modbus-station.md verified
CI Server as Modbus slave (mirror eqpmdcmem + eqpmdcslvtcp) tasks/modbus-station.md §1 verified (started by hand; start file see task)
Read-only equipment manager status with eqpdbg system-management task tuning-checks.md verified
Forced scan (eqpfrcscn), hourly statistics (eqpiostat) L40 summary from docs (statistics empty, ISS-021)
Other protocols L41 summary §3.8–3.40 from docs (no hardware)