CI-Eng-Sample

A small, invented sample project that anyone with this repo can load into a CI Server R1.03 test system. Skills use its names in their examples, and every skill task is re-tested against it so that no other project is needed.

Built and tested on CI Server R1.03.00 (unlicensed test system), 2026-09-30.

Load and remove

Test systems only: loading writes to the CI Server database. CI Server must be running. From an elevated prompt, call the scripts by full path (a bare load.cmd may not be found from the current folder):

cmd /c "<repo>\examples\CI-Eng-Sample\load.cmd"
cmd /c "<repo>\examples\CI-Eng-Sample\remove.cmd"
  • Each step prints a summary and writes a .qlo listing; check that Errors is 0.
  • Restart CI Server after loading (stop, then start the CI Service): a new storage group stores no history until CI Server restarts.
  • load.cmd on a system that already has the project reports Exists and changes nothing.
  • remove.cmd takes about 1½ minutes: a storage group can only be deleted after its stop time has passed, so the script sets a stop time one minute ahead and waits. Removing the group also deletes its history.

Current contents

Name Kind Details
CI-Eng-Sample Section Top level
CI-Eng-Sample.TANK1, .PUMP1, .SYSTEM Sections Tank, pump, system monitoring
CI-Eng-Sample.TANK1.LEVEL Item, Real %, format 999.9, limits LL 10 / L 20 / H 80 / HH 90, scale 0–100, stored in CIENG_EVENT; alarming on (ack type CIENG_ACK, area CIENG_TANKS; 16_item_alarm_df.qli)
CI-Eng-Sample.TANK1.INFLOW Item, Real m3/h, format 9999.9, scale 0–500, stored in CIENG_EVENT
CI-Eng-Sample.PUMP1.RUNNING Item, Boolean
CI-Eng-Sample.PUMP1.MODE Item, Integer 0 manual, 1 auto
CI-Eng-Sample.SYSTEM.CPU_LOAD Item, Real Target for intcpumon
CI-Eng-Sample.SYSTEM.DISK_C Item, Real Target for intdskmon (reports used %)
CI-Eng-Sample.SYSTEM.PING_LOCALHOST Item, Integer Target for inttcpmon (1 = reachable)
CI-Eng-Sample.SYSTEM.PROC_ALM Item, Integer Target for intmon (1 = alm process running)
CI-Eng-Sample.PUMP1.RUNNING.RUN_SECONDS Sub-item, Integrator Running time in seconds (adds value × integration granule, itm_int_secs in itm.sup, default 1 s)
CI-Eng-Sample.TANK1.LEVEL.MAX Sub-item, Min-Max Highest level seen
CI-Eng-Sample.DEMO Section Tutorial examples
CI-Eng-Sample.DEMO.COUNTER Item, Integer Counts 1…100, one step per second, written by DEMO.INCR1
CIENG_1S Trigger group Every second
CIENG_INCR Class (traditional) Increments DEMO.COUNTER, wraps at 100; compiled on load
CI-Eng-Sample.DEMO.INCR1 Object Instance of CIENG_INCR
CI-Eng-Sample.TEMPLATES Section Template items for classes
CI-Eng-Sample.TEMPLATES.TPL_REAL Item, Real Template for items that objects create (format 9999.9, scale 0–1000)
CIENG_TANK Class (traditional) Prompt Tank capacity (m3); signal LEVEL = <object section>.LEVEL (trigger on value); creates <object>.VOLUME from TPL_REAL; volume = level × capacity / 100; logs when the level crosses 80; refuses capacity ≤ 0
CI-Eng-Sample.TANK1.CALC Object CIENG_TANK, capacity 200; creates section TANK1.CALC and item TANK1.CALC.VOLUME
CIENG_JFLOW Class (Java) Attaches <object section>.INFLOW; creates <object>.sPerMin = inflow / 60; logs each change
CI-Eng-Sample.TANK1.JFLOW Object CIENG_JFLOW; creates item TANK1.JFLOW.sPerMin (mixed case, as the Java identifier)
CIENG_EVENT Item storage group Event/Item, lifetime 1 week, rollover 1 day
CIENG_SCAN10S Item storage group Scan/Time every 10 s with quality, lifetime 1 day, rollover 1 hour; TANK1.LEVEL, TANK1.INFLOW
CIENG_AGG Item storage group Aggregation 30 min + hourly, lifetime 4 weeks, rollover 1 week; TANK1.LEVEL max/min/average (values not yet seen, ISS-040)
CI-Eng-Sample.PLC1 Section Modbus loopback station
CI-Eng-Sample.PLC1.COMM_OK Item, Boolean Status item of station CIENG_PLC (1 = communicating, status 22 when off-scan)
CI-Eng-Sample.PLC1.SETPOINT / .READBACK Items, Integer Written to holding register 1 (RO:1) / read from input register 1 (RI:1), same memory
CI-Eng-Sample.PLC1.CMD / .FEEDBACK Items, Boolean Written to coil 1 (DO:1) / read from input bit 1 (DI:1), same memory
CIENG_MB_LINE Modbus line (TCP/IP) Equipment manager EQPCIENG (created and started by loading the line)
CIENG_PLC Modbus station Open Modbus/TCP to localhost:5020, unit 1, output method On change and connect
CIENG_SCAN1S Modbus scan type 1000 ms
CI-Eng-Sample.UA Section OPC UA loopback station
CI-Eng-Sample.UA.COMM_OK Item, Boolean Status item of station CIENG_UA (1 = connected)
CI-Eng-Sample.UA.LEVEL_COPY Item, Real TANK1.LEVEL read back through CI Server's own OPC UA server
CI-Eng-Sample.UA.SRV_STATE Item, Integer OPC UA server state node (ns 0, i=2259), 0 = Running
CIENG_UA_LINE OPC UA client line Client process OPXCIENG (created and started by loading the line)
CIENG_UA OPC UA station opc.tcp://localhost:34493, Basic256Sha256 / SignAndEncrypt, anonymous; subscription CIENG_SUB (1 s); points LEVEL, SRV_STATE
OPC visible Flags Sections CI-Eng-Sample, TANK1 and item TANK1.LEVEL are OPC visible, item read-only (12_opc_visible_df.qli)
CIENG_ACK Acknowledgement type Every alarm needs an acknowledgement; return to normal automatic only if the alarm was acknowledged (same matrix as MANUAL)
CIENG_TANKS Area of interest Label for tank items (TANK1.LEVEL AOI_1)
CIENG_TANK1 Alarm selection area SECTION = "CI-Eng-Sample.TANK1", compiled on load
CIENG_VIEWER Authorization group Read-only: ITEM_READ, SECTION_READ, ALARM_CURRENT_READ, ALARM_CHRONO_READ. No users are created by the sample.

Items created by objects (TANK1.CALC.VOLUME, TANK1.JFLOW.sPerMin) and their sections are deleted with the objects; they are not in 02_item_df.qli.

All items except PLC1.* are internal (no station). The PLC1 station talks to CI Server's own Modbus slave mirror (see below), so no PLC is needed either. New items start with status 13 (NOT INIT) until a value is written.

Files

File Purpose
01_section_df.qli Sections (SECTION_DF); parents before children
02_item_df.qli Items (ITEM_DF)
02b_sub_item_df.qli Sub-items (SUB_ITEM_DF)
03_his_group_df.qli Item storage groups (HIS_GROUP_DF): event, scan, aggregation
04_item_his_df.qli Items in the storage group (ITEM_HIS_DF, name <group>:<item>)
05_trigger_df.qli, 06_class_df.qli, 07_object_df.qli Trigger group; classes (source in the METHOD memo, @" … "@, COMPILE 1; Traditional and Java); objects (ATTR_VALUE_1 = prompt answer)
08_auth_group_df.qli Authorization group (AUTH_GROUP_DF)
09_modbus_line_df.qli, 10_modbus_station_df.qli, 11_item_eqp_df.qli Modbus line; station, scan type, points; items connected to points
12_opc_visible_df.qli OPC visible / read flags (loaded with dssqld -m)
13_opcua_line_df.qli, 14_opcua_station_df.qli, 15_item_opcua_df.qli OPC UA client line; station, subscription, points; connected items
01b_alarm_df.qli Alarm definitions: acknowledgement type, area of interest, alarm selection area (ALARM_ACK_DF, ALARM_AOI_DF, ALARM_ASA_DF)
16_item_alarm_df.qli Switch on alarming for TANK1.LEVEL (loaded with dssqld -m)
equipment/eqpciengslv_start.cmd, _stop.cmd Start/stop the Modbus slave mirror (copy to tls\com)
76_…93_remove_*.qli Names to delete, in reverse order (alarm definitions last, 93)
load.cmd, remove.cmd Run the steps in the right order
monitoring/*.sup.txt Setup-file lines for the monitoring processes (not applied by load.cmd)

Modbus slave mirror (for station CIENG_PLC)

CIENG_PLC reads and writes CI Server's own Modbus slave: eqpmdcmem (slave memory) and eqpmdcslvtcp (Modbus TCP on port 5020). Without them the station reports bad communication (COMM_OK = 0) but everything loads. To start them with CI Server, an administrator copies equipment/eqpciengslv_start.cmd and eqpciengslv_stop.cmd to %TLS_ROOT_PATH%\tls\com; for a quick test they can also be started by hand from a normal prompt:

start eqpmdcmem -n EQPMDCMEM
start eqpmdcslvtcp -n EQPMDCSLVTCP -p 5020

Remove the two files from tls\com when the sample is removed. See skill equipment, task modbus-station.md.

OPC UA loopback (station CIENG_UA)

CIENG_UA is CI Server's OPC UA client connected to CI Server's own OPC UA server, so no external server is needed. The first connection on a system needs a one-time certificate exchange, done by the user (skill data-access, task opcua-client.md §4):

  1. After loading, the client logs OPXC-E-CER_NO_TRU; trust the server certificate in %TLS_ALLUSERS_PATH%\pki\opxuac\pkiclient\rejected (Engineering Module, or move it to …\pkiclient\trusted\certs).
  2. The server then rejects the client; move CI_SERVER_OPCUA_CLIENT_OPXCIENG […].der from %TLS_ALLUSERS_PATH%\pki\opxuas\pkiserver\rejected to …\pkiserver\trusted\certs (PowerShell: Move-Item -LiteralPath, the name contains brackets).

Then UA.COMM_OK = 1 and UA.LEVEL_COPY follows TANK1.LEVEL. The trust is kept when the sample is removed and loaded again.

Alarms (TANK1.LEVEL)

TANK1.LEVEL raises HIGH above 80 (Alarm 2, priority 2) and HIGH HIGH above 90 (Alarm 3, priority 1). To try it on a test system: itmval -p -n CI-Eng-Sample.TANK1.LEVEL -v 85, export ALARM_CURRENT (filter on ITEM_NAME), acknowledge with dssqld -m on ALARM_CURRENT (NAME, ACK 1), write the level back below 80. See skill alarm-management, task item-alarming.md.

Monitoring processes (optional)

monitoring/ holds the lines to add to the setup files in %TLS_ROOT_PATH%\tls\sup\ so that intcpumon, intdskmon, inttcpmon, intmon and intspawn write into the SYSTEM items. These change the system's own setup files: back the files up first and restore them after testing. See the system-management skill, task monitoring-processes.md.

Planned additions

Phase Adds
10 A display and symbol
11 A report

Rules

  • Test systems only; invented names only, no real plant or customer data.
  • Keep the load order: sections → template items → classes (compiled) → objects → other items → storage groups → items in storage groups (IM 36K10J10 §5.6). Keep remove.cmd in reverse order.
  • Every file notes the CI Server version it was built and tested on.