# R1.05 verification checklist
Two kinds of R1.05 checks are open after the read-only re-check of 2026-10-08:
- **Not tested:** the function is not available on the R1.05 test server, so it cannot be
tested there at all. The content stays "from docs" and is marked **not tested** with the
reason. Nothing to do until a suitable system exists.
- **Awaiting user verification:** Claude could not run the step itself (refused as a remote
command, needs an administrator, needs the GUI). Claude prepared the steps and expected
results below; the user runs them on the server or in the GUI and sends the output or a
screenshot, and Claude records the result in the task file and in `progress.md`.
All steps below are read-only: they open forms or print information and save nothing.
Close every form with *Cancel*.
## Not tested on the R1.05 test server
| Area | Reason | Where marked |
|---|---|---|
| IT Security Tool (version 2.0 / 3.0), `CIX_` groups, `CTM_PROCESS`, LAPS, GPO import | Tool not installed; Windows Server 2025 is not supported by the tool | skill `installation-security`, C10/C30 summaries |
| Vnet/IP drivers, VAGW Bossd | No Vnet/IP card; not supported on Server 2025 | skill `installation-security`, C10 summary |
| Upgrade from R1.03/R1.04 with the automatic configuration merge (`jupgutl`, `-c` argument) | Fresh R1.05 install, no upgrade to observe; an upgrade test needs a separate machine | C10 summary, ISS-086 |
| CI Server with PRM | No PRM | C10 summary, ISS-090 |
| IEC 60870-5-104 and IEC 61850 (EQT managers, report control blocks, `eqtdbg`, `eqtfrcscn`) | No device and no EQT line on the server | skill `equipment`, L40/L41 summaries, ISS-076–079 |
| OPC A&E `OPXAES_DIR_ALM`, OPC UA PubSub, imported information model | Needs another client/server or extra server instances | skill `data-access`, ISS-085 |
## Awaiting user verification
### V1. `eqpdbg` main info (skill `equipment`, L40 summary §3)
On the R1.05 test server, in a normal command prompt:
```
eqpdbg 0 EQPMDC
```
Type `1` (Get main info), Enter, read the output, then `-1` (Exit). Expected: line type 107,
the Modbus line(s) attached, scan interval (tick) in ms, number of slaves, line load %.
Do not choose any other action number. Send a screenshot of the output.
### V2. Setup check script (skill `installation-security`, task `setup-check.md`)
Copy `tools/setup_check.ps1` from this repo to a scratch folder on the server, run it in an
**elevated** Windows PowerShell, then delete the copy:
```
powershell -NoProfile -ExecutionPolicy Bypass -File setup_check.ps1
```
Expected (from the one-by-one checks of 2026-10-08): CI Server 1.05.00 OK; Windows Server 2025
Datacenter shown as not in the list; DIFF for firewall domain profile, Defender, automatic
updates, defrag / component cleanup, page file, .NET 3.5, missing `CIX_` groups; CHECK lines
for IT security. Send the result table (screenshot or text).
### V3. Engineering Module forms (skill `data-access`)
In the Engineering Module on the server (log on as a user with engineering rights), open each
form below, take a screenshot, and close it with *Cancel*:
1. *Tools › OPC UA Information Model Mapper*: the mapper window opens (shows *New Mapping*).
2. *Authorisation › Users*, any user: the *Add API Key* function exists (do not create a key).
3. An OPC UA client point form (*New* on an OPC UA station is enough to see it, then
*Cancel*): the checkbox *Read additional node information* exists.
4. An OPC UA client method form: fields for node ID type, *Options* tab (parent object node ID)
and *Arguments* tab; no process-area field.
If no OPC UA client line exists on the server, steps 3–4 need one: skip them and say so.
### V4. Needs a decision first: CI-Eng-Sample on the R1.05 test server
The sample tasks (Modbus mirror station, OPC UA loopback, items, alarms …) can only be
re-tested on R1.05 by loading `CI-Eng-Sample` (all names `CIENG*`) onto the shared server. It
adds records and starts extra equipment processes (`EQPCIENG` on port 5020), but touches no
other project's records. Load only after the user approves; otherwise these tasks stay
"verified on R1.03, files checked identical on R1.05".