Summaries of IM 36K10L50, P30, P20, R40, C30 and E10 (R1.03). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
4.8 KiB
| manual | title | edition | version | status |
|---|---|---|---|---|
| IM 36K10R40-01EN | Report Server Setup | 3rd Edition, Sep. 2023 | R1.03 | processes, start/stop scripts, rptman.sup and the generator set-up files checked on the test system; interactive generator and rptstp verified 2026-10-01; separate server processes, extra generators and custom destinations from docs |
Report Server Setup (R1.03)
How REPORT Service is built and configured. Writing reports: IM36K10P20-01EN.md (RQL) and
IM36K10C30-01EN.md (Engineering Module). Section numbers refer to the manual.
1. Parts (§1)
| Block | Process | Job |
|---|---|---|
| Manager | RPTMAN |
Stores report definitions, schedules (through HISTORY Service), event triggers and ad-hoc requests; hands generation to a generator; manages generated reports |
| Generator | RPTGE1 (executable rptgen) |
Runs the RQL of a report and writes the result; ad-hoc queries use copies of the generator |
| Report stopper | rptstp <generator>… |
Cancels the report a generator is working on |
| Info servers (RPI) | rpidic, rpidis (DSS dictionary), rpidix (DSS data), rpifil, rpiitm, rpihis, rpialm, rpievt, rpiopc, rpicif |
Fetch data for the generator; linked into the generator by default — separate processes only when the data lives on another node |
Default layout (installed): one node, servers linked into rptgen; report_start.cmd (in
tls\com) refuses to start when HISTORY Service is not running, then starts rptman and
rptgen -n rptge1. The separate rpi* lines and a second generator (rptge2) and rptgsp
are present but commented out. report_stop.cmd stops rpt* and rpi* with durstp.
Full functionality needs BUS, DATABASE, HISTORY, ITEM, AUDIT, PROCESS Services and INTEGRATION.
2. Setup files (§2.2)
tls\sup\rptman.sup(manager):HIS = <node>, <name>, <task>(default0, HIS, 0),DUR_QUEUE_SIZE(500 KB).FPATH/SPATHare not used. Installed:his = 0, HIS, 0,dur_queue_size = 500. Also present:rptini.sup(only a licence-like value, undocumented).- Generator set-up descriptions are RQL files with extension
.rpt, named after the instance:rptge1.rpt(background generator) — installed:@workspace 500,@page_size 66,@width 120,@left_margin 1,@top_margin 1, header (line, customer name centred, description right,Report of DD-MMM-YY, line), footer (line, report name,page n, line),dictionary rpidis.'tlsdic';,login rptman;(priority 0). Every background report gets this layout unless its query overrides it.rptgen.rpt(interactive) — noLOGIN(that is what makes the generator interactive),@page_size 23,@formfeed 0,@workspace 100.rptgsp.rpt— a spare generator withlogin rptman, 9(not started by default). Documented defaults when a variable is not set: top 3, bottom 6, left/right 0, width 80 (40–512), page 72 (20–255), sort space 100 KB, workspace 500 KB (C30 and P20 say 16 KB, ISS-047).
DICTIONARYin the set-up file chooses the dictionary server/node; defaultrpidis.'tlsdic'(file%TLS_DAT_PATH%\tlsdic_dss.dic).
3. More generators (§2.4)
Add start /B /NORMAL %TLS_ROOT_PATH%\tls\exe\rptgen -n rptge2 to report_start.cmd and a
tls\sup\rptge2.rpt ending with LOGIN rptman, <p>;. A generator only takes reports with a
priority ≥ its own; one generator must keep priority 0. Higher-priority reports are generated
first. Admin rights and a restart needed (not practiced).
4. Layout defaults (§3.1, §3.2)
Put shared header/footer/margins in the set-up file (or a new .rpt given with -s).
@export 1 gives comma-separated output (for files read by other programs). Memory: @workspace
(strings, records), @sortspace (ORDER/GROUP BY; spills to tls\lst when too small).
5. Destinations (§3.3)
The Engineering Module offers file, printer and system log destinations; R1.03 adds printer
management devices and destinations (IM36K10C30-01EN.md §3). Adding a new built-in destination
means changing rpt_print.c (not shipped as buildable on the test system), re-linking rptman
and adding a list entry to report_val.dss (dss -d) — system integrator work, not practiced.
6. Interactive mode (§4) and stopping (§5)
rptgen -s rptgen.rpt starts a foreground generator (prompt RPT>); end with QUIT;. Useful to
try RQL and inspect datasets without defining a report. rptstp rptge1 cancels the running
report of RPTGE1 (also the Cancel button / REPORT_DF.CANCEL).
Verified 2026-10-01: piped input works (rptgen -s rptgen.rpt < query.rql), set
SET @NEXT 0; first or every page waits for Enter. rptstp rptge1 stopped an endless loop
report within seconds; GENERATE went back to 0, an empty generated report was stored, the
generator stayed running and took the next report normally. Task: skill reporting.